SRM Tunes PVDF Distillation Membranes with Tech Inc. Polymer and Contact Angle Meter

At a glance. You can change a membrane without changing its polymer: change the bath it forms in. At SRM Institute of Science and Technology, a team cast PVDF membranes for membrane distillation and swapped part of the water coagulation bath for n-butanol. The PVDF and NMP came from Tech Inc., and hydrophobicity was measured on a Tech Inc. contact angle meter.
Why this matters
Membrane distillation only works if the membrane stays dry inside: liquid water must not enter the pores, only vapour. PVDF is popular for its processability, but it is less hydrophobic than PTFE. Finding simple ways to raise its hydrophobicity, without fluorinated coatings, makes PVDF distillation membranes more practical.
What the team did
Nanditha Dayanandan, Kavin Kalyaan Marappan Palanisamy, Ashish Kapoor and Sivaraman Prabhakar dissolved 16 wt% PVDF in NMP, degassed the dope, cast films on a polyester support and immersed them in coagulation baths ranging from pure water to pure n-butanol. They measured porosity, water contact angle, permeate flux and liquid entry pressure for each membrane.
Where Tech Inc. came in
Tech Inc. supplied the PVDF polymer and the NMP solvent (anhydrous, 99.9%) for the dopes. The team measured water contact angle on a Tech Inc. Economy model contact angle meter, which captures the droplet image and calculates the angle by image analysis. For a study whose main outcome is hydrophobicity, that measurement is the result.
Results that stand out
Contact angle rose as the share of n-butanol in the bath increased.
The membrane formed in 100% n-butanol was the most hydrophobic of the series.
Porosity also increased with the n-butanol content, in line with the contact angle trend.
The authors conclude that bath composition alone can tailor PVDF membranes for distillation.
What it means for your lab
Contact angle is the first test on any distillation or anti-fouling membrane. Our TICONT contact angle analysers range from portable units to automated goniometers, and our contact angle testing service measures samples for you. See contact angle measurement in membrane research. The same SRM group also ran phenol extraction and acetic acid extraction on Tech Inc. membrane contactors.
The paper
Dayanandan, N., Marappan Palanisamy, K. K., Kapoor, A. and Prabhakar, S. (2021). Influence of n-butanol composition on membrane performance in coagulation bath for membrane distillation. Journal of Physics: Conference Series 2007, 012043. doi:10.1088/1742-6596/2007/1/012043
Read the full paper at the publisher for methods, data and figures.
Part of the Research with Tech Inc. series
This post is one of a series on published research made with Tech Inc. equipment and materials. See the full list on Research using Tech Inc. equipment. Next in the series: SRM Recovers Phenol from Wastewater with a Tech Inc. Hollow Fibre Membrane Contactor.
Published with our equipment? Send the reference to mail@techincresearch.com and we will feature your work. To discuss equipment for a similar study, call +1 (289) 622-1032 or write to mail@techincresearch.com.





Comments