SRM Recovers Phenol from Wastewater with a Tech Inc. Hollow Fibre Membrane Contactor

At a glance. Phenol is toxic in wastewater but worth money once recovered. At SRM Institute of Science and Technology, a team extracted it with three long-chain alcohols through a Tech Inc. PVDF hollow fibre membrane contactor, removing up to 94.8 per cent with less solvent, less energy and a safer process than conventional extraction.
Why this matters
Solvent extraction recovers phenol well, but in conventional mixer-settlers it needs large solvent inventories, energy for mixing and separation, and careful handling of flammable liquids. That has kept it out of most wastewater plants. A membrane contactor keeps the solvent and water on opposite sides of the fibre wall, so there is no emulsion to break and far less solvent in the system.
What the team did
Elangovan Poonguzhali, Fathima Aadilah Mohamed Ali, Ashish Kapoor and Shashank Prabhakar compared 1-hexanol, 1-octanol and 1-decanol for phenol extraction, first in conventional solvent extraction and then in membrane-assisted solvent extraction through a PVDF hollow fibre contactor. They also studied the thermodynamics of the extraction and ran the contactor over a long period.
Where Tech Inc. came in
The membrane-assisted runs used a Tech Inc. PVDF hollow fibre membrane contactor. PVDF fibres resist alcohols and phenol, and the module design lets the solvent run either through the fibres or around them. See our hollow fibre membranes and the guide to hollow fibre modules.
Results that stand out
Conventional extraction removed 96.24% of phenol with 1-hexanol, 95.97% with 1-octanol and 92.87% with 1-decanol (solvent to feed ratio 2.5:1, 500 mg/L phenol).
Membrane-assisted extraction removed 94.82%, 91.01% and 89.35% respectively, at a lower solvent to feed ratio of 2:1.
The extraction was exothermic with all three solvents.
The membrane route needed less solvent and less energy, and was simpler and safer to operate.
What it means for your lab
Contactors suit any liquid-liquid extraction where emulsions, solvent losses or safety are a problem, as well as gas absorption and degassing. We build modules in PVDF, PES, PP and PTFE so the fibre and housing materials can be matched to the solvent. The same group's acetic acid study used a Tech Inc. PES contactor.
The paper
Poonguzhali, E., Mohamed Ali, F. A., Kapoor, A. and Prabhakar, S. (2022). Performance of membrane assisted solvent extraction with homologous solvents for the removal and recovery of phenol. Desalination and Water Treatment. doi:10.5004/dwt.2022.28117
Read the full paper at the publisher for methods, data and figures.