SDI and MFI Analysers Compared: Automatic, Online and Manual (ASTM D4189)

Bottom line: for unattended RO feed monitoring choose the Silton 4950 Pro, which changes its own filter. Seawater plants need the Pro Max or the non-metallic Pro Max II. Spot checks need only the manual kit.
Side by side
Instrument | Type | Index and range | Filter | Channels | Wetted parts | Outputs |
|---|---|---|---|---|---|---|
automatic online | SDI-5, 10, 15 to ASTM D4189 | 0.45 µm roll, changed automatically | 1 (2 optional) | AISI 304 | 4–20 mA with HART; RS-485 Modbus RTU; alarm contact | |
automatic online | SDI-5, 10, 15 | roll, automatic | as the Pro | as the Pro | adds Ethernet (Modbus TCP) and three relays | |
automatic, seawater | SDI-5, 10, 15 | roll, automatic | 2 | 316L; EPDM or fluoroelastomer seals | 4–20 mA with HART; RS-485 | |
automatic, non-metallic | SDI-5, 10, 15 | roll, automatic | 2 | non-metallic path; super duplex valve bodies | 4–20 mA with HART; RS-485 | |
online | SDI to ASTM D4189 | 47 mm disc, fitted for each test | 1 | – | 4–20 mA | |
online, heavy duty | SDI 0 to 6.6 | 47 mm disc | 1 or 4 | 316L; super duplex or non-metallic on request | – | |
automatic MFI | MFI-0.45 (s/L²) | roll, automatic | – | – | 4–20 mA; RS-485; alarms | |
online MFI | MFI-0.45 | 47 mm disc | – | – | 4–20 mA; alarms | |
manual kit | SDI-15 0 to 6.7 | 47 mm, 0.45 µm MCE | – | stainless holder | – | |
manual kit, seawater | SDI-15 0 to 6.7 | 47 mm, 0.45 µm | – | super duplex or non-metallic | – |
All automatic and online SDI analysers test at 2.07 bar (30 psi), as ASTM D4189 requires.
How to choose
Unattended monitoring: automatic roll change removes the operator from every test.
Seawater and brackish feeds: pick 316L, super duplex or non-metallic wetted parts.
Control-room link: choose the outputs your PLC or SCADA reads.
Fouling studies beyond SDI: MFI-0.45 gives a value that is proportional to the fouling rate.
All models: SDI measurement range. Calculate SDI yourself with our SDI calculator.
Before you order
Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.





Comments