Sampling Systems Compared: Pressure, Temperature, Materials and Sample Size

Writer: Tech Inc
Tech Inc
5 hours ago
7 min read
Sampling Systems Compared: Pressure, Temperature, Materials and Sample Size

Bottom line: for closed sampling of process liquids, the closed-loop spot samplers fill bottles, cylinders or vials on lines rated up to Class 1500; gases need the gas sampling panel. Hot streams need a cooler panel or the steam sampling system. For custody transfer, the in-line sampler mounts on a probe in the line, the power-mixing system suits low or variable line velocity, and the natural gas composite sampler covers gas to GPA 2166.


The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.


Process sampling systems, panels and closed samplers

Product

Models

Pressure

Temperature

Wetted materials

Sample size and notes

TI-LSS-1, 2 and 4 sample points

up to 150 bar (2,180 psi)

-40°C (−40 °F) to 400°C (752 °F), with cooling coil

SS316, SS304, Hastelloy C-276, PTFE-lined

open or closed; bottle or cylinder

TI-GSS-1, 2 and 4 sample points

up to 100 bar (1,450 psi)

-20°C (−4 °F) to 350°C (662 °F)

SS316, SS316L, Inconel, PTFE

multi-stage coalescing filtration; heated enclosure option

TI-SWAS-4 to TI-SWAS-16 sample points

sample inlet up to 250 bar (3,630 psi)(g)

inlet up to 600 °C (1,110 °F); outlet cooled to 25 °C (77 °F) nominal

SS316, SS316L, duplex

online analysers or grab samples; isokinetic nozzles to ASTM D1066

–

maximum operating 1500 psi; design and hydrotest 3000 psi

design 200 °F

INCONEL 625 to NACE MR0175 / ISO 15156

7 L flash drum; 1 L closed bottle; Class 1500 RTJ tie-ins; no utilities

–

design 1500 psi

design 230 °F

INCONEL 625 to NACE MR0175 / ISO 15156

7.41 L flash drum; 4 L bottle; level and temperature monitoring

TI-CLL-B, C and V

line rating up to Class 1500

–

SS316/316L, duplex 2205, super duplex 2507, 6Mo, Monel 400, INCONEL 625, Incoloy 825, C-276, PTFE-lined

bottle 250 to 1,000 mL, sample cylinder or septum vial

TI-GSP-300 to TI-GSP-1500

Class 300 to Class 1500

–

SS316L; Monel, INCONEL 625 and C-276 on request

single- or double-ended cylinders; vent to flare or closed vent

TI-LHS-L, N and H

–

–

SS316L; alloys on request

outage-tube and floating-piston cylinders; nitrogen purge

TI-SCL-100, 300, 600 and PR

to the sample point design, including high-pressure steam

–

SS316; INCONEL or Hastelloy tube options

sample flow to about 100, 300 or 600 L/h

TI-MSC-L1, G1, C1 and M4

to about 100 bar (1,450 psi); higher on request

–

316L; Monel, Hastelloy or duplex on request; NACE MR0175 / ISO 15156 for sour service

bottles 250 mL to 1 L; cylinders 150 mL to 1 L; IP65 stainless cabinet

TI-TCP-150, 300, 400 and E

to about 100 bar (1,450 psi), depending on model

inlet to about 400 °C (752 °F); outlet typically below 40 °C (104 °F)

316 stainless; alloy coils on request

cylinder or bottle; cooling water about 0.5 to 2 m³/h

TI-JFS-25, 100, 250 and V

to about 40 barg (580 psig)

to about 350 °C (662 °F); higher on request

316L, duplex or Alloy 625

about 25 to 250 mL; steam, thermal oil or electric jacket

TI-CVS-10 to TI-CVS-100 and H

to about 50 barg (725 psig); higher on request

to about 200 °C (392 °F); jacketed version higher

316L; duplex, Alloy 625, C-276 or PTFE-lined on request

fixed chamber about 10 to 100 mL

–

designed to ASME VIII or client specification

–

SS316L, PTFE seals

150–250 ml; nitrogen purge and return to process

TI-VRS-50, 100, 250 and H

full vacuum to about 6 barg (87 psig)

to about 200 °C (392 °F); heated version higher

316L, C-276, glass-lined or PTFE-lined

about 50 to 250 mL

TI-NHS-L, G, A and E

to about 25 barg (363 psig)

–

316 stainless; no copper or brass

liquid ammonia cylinders 150 to 500 mL

TI-CSX-C, B, G and E

to about 40 barg (580 psig)

–

Monel 400 for HF; C-276 or PFA-lined for chlorine, HCl and chlorosilanes

cylinder 75 to 500 mL; bottle 100 to 1,000 mL; vent to scrubber

TI-PCS-H, T, DP and HT

air supply about 3 to 6 bar (44 to 87 psi)

–

316L and PTFE

bottle about 100 mL to 1 L; dip depth to about 1.2 m (handheld) or 3 m (trolley)

TI-SPS-C, L, N2 and T

atmospheric to about 6 barg (87 psig) for line samplers

to about 200 °C (392 °F)

304 or 316 stainless

about 50 to 250 mL per cut; nitrogen purge for air-sensitive solids

TI-HQS-1, 2 and F

dispenser pressure class 35 or 70 MPa

–

SS316L, cleaned and passivated

samples for testing to ISO 14687; particulate filter holder option

TI-CPW-1, 3, CW and CR

–

–

316 stainless

about 0.1 to 1 L/min per point; 0.45 µm membrane filters

TI-ASC-P, C, S3 and S6

–

–

SS316L tubing and fittings; alloys for sour or corrosive service

panel, cabinet or walk-in shelter of about 3 or 6 m

TI-OAP-600, 1000, 1400 and H

–

–

316 stainless frame and plate

about 600 to 1,400 mm wide, about 2.2 m high with canopy; Zone 1 or 2 components

TI-MSM-FS, C, SS4, SS8 and CAL

to about 34 barg (500 psig)

to about 120 °C (248 °F)

316L; C-276 or inert coatings on request

1.5 inch surface-mount footprint; one to eight streams

TI-CEMS-G, GP and GPF

–

–

–

SO2, NOx, CO, CO2, O2, PM and flow; extractive or in-situ


Automatic sampling for custody transfer

Product

Models

Size

Pressure

Wetted materials

Notes

TI-ILS-20, 40 and 60

receivers about 20 to 60 L; lines 2 in and larger

to the line rating

SS316L; duplex and alloys on request

probe-mounted, flow-proportional; Ex-rated equipment

TI-FLS-1, 15 and 2

1 to 2 inch loop

–

SS316L

centrifugal or progressive cavity pump, Ex rated

TI-PMS-6, 12, 24 and 36

lines up to 6, 12, 24 or 36 inch

–

SS316L; duplex on request

dispersion held across the full metered flow range

TI-PHS-1, 2 and 4

floating-piston receivers about 1 to 4 L

Class 600 to Class 1500 typical

SS316L

nitrogen pre-charge keeps the sample above bubble point

TI-NGS-300, 500, 1000 and T

300 to 1,000 mL constant-pressure cylinder

–

SS316

GPA 2166 and ISO 10715; flow- or time-proportional

–

–

–

–

110 or 230 V AC, or 24 V DC; Modbus RTU and TCP/IP; IP65 or Ex enclosure

TI-SRM-5 to TI-SRM-50

about 5 to 50 L

ASME Section VIII or PED as required

SS316L

pump loop or mechanical mixer

–

grab volume set to the batch size

to the pipeline design conditions

to the pipeline design conditions

API MPMS 8.2 / ISO 3171; mounts on the existing probe nozzle

TI-CPR-1L-316

typically 1 L

to suit the sampled line

SS316

inert gas pre-charge at or above line pressure


Cylinders, components, laboratory equipment and spares

Product

Models

Size

Pressure

Materials

Use

TI-SCY-150 to TI-SCY-3800

about 150 mL to 3.8 L

about 124 bar (1,800 psi) or 345 bar (5,000 psi)

304L or 316L; inert coating on request

ASTM D1265, GPA 2174 and ISO 10715 practice

TI-RVP-P300, P1000, F500 and K

about 300 mL to 1 L

to about 100 bar (1,450 psi), piston type

316 stainless; FKM or FFKM seals

before ASTM D323, D5191 and D6377 tests

–

–

up to Class 1500

SS316/316L, duplex 2205, super duplex 2507, 6Mo, Monel 400, INCONEL 625, Incoloy 825, C-276

EN 10204 Type 3.1 certificates; PMI on every heat

TI-GFD-P400, C200, M100, D100 and E

elements about 0.01 to 40 µm

to about 400 bar (5,800 psi) particulate; about 100 to 200 bar (1,450 to 2,900 psi) others

316L; C-276 or inert coatings on request

sample and instrument gas

–

to the laboratory's cylinder sizes

–

SS316L

bench-top or wall-mounted

TI-SCC-4, 8, 12 and A

cylinders about 150 mL to 3.8 L

vacuum to about 0.1 mbar

316 manifold; PTFE seals

nitrogen purge heated to about 120 °C (248 °F)

TI-BSR-1, 3, 6 and C

bottles about 50 mL to 1 L; recovery drum or tank about 20 to 200 L

nitrogen at low pressure

316 stainless; PTFE seals

earthing and bonding to IEC 60079-32-1 guidance

TI-SCK-B, N, C, S and A

bottles about 50 mL to 1 L

–

glass, coated glass, HDPE or PFA bottles; 316 needles

batch number on every pack

TI-DGA-S4, B6, C and R

gas-tight glass syringes of about 50 mL

–

glass syringes; amber glass or aluminium bottles

IEC 60567 and ASTM D923 practice

TI-SWC-COL, R, CC, F and A

about 0.5 to 1.5 L of resin per column

–

acrylic or polycarbonate column; 316 cooler coils

ASTM D6504 and ASTM D1066 practice


How to choose

  • Keep the sample representative: take it where the stream is well mixed, and flush dead volume before every sample.

  • Protect the operator: closed sampling keeps toxic, flammable and hot fluids out of the open air.

  • Keep the light ends in: volatile and pressurised samples need cylinders with floating pistons or outage tubes, not open bottles.

  • Cool hot samples before they reach the container, and choose wetted materials for the fluid, including sour and corrosive service.

  • For custody transfer, the sampler, controller and receivers must work as one system to the standard named in your contract.



Before you order

Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.


Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.