The Tech Inc. Ammonia Sampling System takes representative samples of liquid or gaseous ammonia into sealed cylinders for quality analysis, without releasing ammonia at the sampling point. The loop is flushed before sampling, the cylinder is filled and isolated, and the lines are purged with nitrogen to a safe vent or scrubber.
At a glance: liquid or gas samples · cylinders 150 to 500 mL · to about 25 barg · 316 stainless, no copper or brass · nitrogen purge to vent or scrubber
Main components
- Closed sampling loop with block and isolation valves
- Stainless steel sample cylinder with valves and quick-connects
- Nitrogen purge and vent connections
- Pressure gauge and, for liquids, an outage tube in the cylinder
- Enclosure or panel with drip tray and instructions plate
- Optional heated vaporiser for gas-phase analysis
Applications: ammonia and fertiliser plants, ammonia storage terminals and ships, and ammonia projects for hydrogen transport and fuel.
Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.