top of page

Hollow Fibre Membrane Making Equipment Compared: Spinning Lines, Spinnerets and Module Building

Writer: Tech Inc
Tech Inc
6 hours ago
3 min read
Hollow Fibre Membrane Making Equipment Compared: Spinning Lines, Spinnerets and Module Building

Bottom line: start fibre development on the lab hollow fibre casting machine and interchangeable spinnerets. Move to the pilot spinning line for longer runs, and to the commercial line for 2 to 8 spinnerets. Build modules with the potting centrifuge, resin dosing machine and guillotine, then check them on the integrity tester.


Spinning, coating and post-treatment

Machine

Scale

Speed

Dope and spinneret

Other data

laboratory

adjustable take-up speed

dope and bore metering pumps; interchangeable spinneret tips

coagulation bath with temperature control; adjustable air gap; PVDF, PES, PSf, PAN

laboratory

take-up up to about 30 m/min

single or multi-hole spinneret

bath about 1 m; draw ratio set by godet speeds

pilot

up to about 50 m/min

heated dope tank 5 to 50 L; single, multi or dual-layer spinnerets

air gap 0 to 30 cm

production

5 to 60 m/min

2 to 8 spinnerets; dope up to 120 °C (248 °F)

SS304 or SS316 wetted parts

1, 4 or 8 braids

2 to 30 m/min

dope up to 90 °C (194 °F)

braid about 1.5 to 2.5 mm

1 or 4 fibres

0.5 to 20 m/min

–

fibre OD 0.3 to 3 mm; oven up to 150 °C (302 °F)

all lines

–

annulus OD 0.5 to 3 mm; needle OD 0.2 to 1.5 mm

SS316 or SS304; heating jacket option

about 50, 200 or 500 L tanks

–

–

water ambient to 80 °C (176 °F); SS304 or SS316


Module building and testing

Machine

Function

Size range

Key data

centrifugal potting of fibre bundles

modules to 0.3, 0.7 or 2 m

variable speed up to several hundred rpm; chamber ambient to 60 °C (140 °F); PU and epoxy

doses and mixes two-component resin

heated tanks 5 to 30 L

ratio 100:10 to 100:100; shot about 5 g to 2 kg; PU, epoxy, silicone

cuts potted hollow fibre modules

module diameter up to about 110 mm

hardened stainless blade; manual or pneumatic; guard and two-hand control

pressure decay, bubble point and diffusion tests

modules up to about 2 m

test pressure up to 3 bar (44 psi)

bench-scale membrane bioreactor for module trials

–

submerged module; aeration for biology and air scour; suction pump


How to choose

  • Fibre development needs fine control of dope, bore fluid, air gap and take-up speed, so start in the laboratory before committing to a line.

  • Spinneret geometry sets fibre size and wall thickness: choose the orifice count and sizes for your target fibre.

  • Reinforced or composite fibres need a braid or coating line rather than a plain spinning line.

  • Plan potting, cutting and integrity testing with the spinning line so module lengths and diameters match.



Before you order

Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.


Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.