Process Note: How Flare Gas Recovery Works Without Compromising Safety

At a glance. A flare is a safety system, but in many refineries, petrochemical plants and gas plants it also burns a steady stream of routine gas from purges, leaking relief valves and process vents. That gas has fuel value, and burning it produces CO2 and sometimes smoke and noise. A flare gas recovery unit (FGRU) compresses the routine flow back into the fuel gas system, while the flare remains instantly available for emergency releases. Operators across the world fit them to cut fuel costs and emissions together.
How the process works
Flare header. All relief and vent streams collect in the flare header and pass through a knock-out drum.
Liquid seal or fast-opening valve. A water seal drum, or a staged fast-opening valve, holds a small back pressure on the header. Routine flow cannot lift the seal, so it goes to the recovery compressors instead of the flare.
Compression. Compressors, often liquid ring machines because they tolerate liquids and varying gas, raise the gas to fuel gas pressure.
Separation and treatment. The compressed gas is separated from the seal liquid and, where needed, sweetened before it joins the fuel gas system.
Emergency release. When a large release raises header pressure, it breaks through the seal or opens the staging valve and goes straight to the flare.
Design points
Routine flow profile. Measured or estimated base flows, peaks and composition decide compressor number and size.
Header pressure control. Recycle and staged compressors keep header pressure within a narrow band so air is never drawn in and the seal is never broken by routine flow.
Oxygen and composition monitoring. Analysers watch for air ingress and for gas qualities the fuel system cannot accept.
Safety integrity. The recovery system must never reduce the flare's ability to relieve; this is reviewed in the hazard studies.
Hydrogen-rich and sour streams need suitable materials and seals.
Common problems
Seal liquid loss or carry-over, which lets gas bypass to the flare or liquid reach the compressors.
Unstable control that cycles the seal and causes flaring spikes.
Fuel system upsets when composition swings are not managed.
Corrosion in seal water systems with H2S and CO2.
Where Tech Inc. equipment fits
Tech Inc. builds flare gas recovery units, tank vapour recovery units, compressor discharge oil-removal coalescers, fuel gas conditioning skids and continuous emission monitoring systems. Each package is engineered to the client's flare data and safety philosophy, built in-house and factory-tested.
Related reading
This note is general guidance. Each unit is designed to the project's process data and the applicable codes and standards.





Comments