Process Note: How a Tank Vapour Recovery Unit Captures Flash Gas

At a glance. When crude oil or condensate enters a storage tank at near-atmospheric pressure, dissolved light hydrocarbons flash out. Filling, emptying and daily temperature swings add working and breathing losses. Venting or flaring this gas wastes product and adds methane and VOC emissions, which regulators across the world now restrict. A vapour recovery unit (VRU) draws the vapour off the tanks and compresses it into a gas line or fuel system.
How the process works
Vapour collection. A header connects the tank vapour spaces. Tanks stay just above atmospheric pressure, protected by pressure–vacuum valves and a blanket gas supply.
Suction scrubber. Liquids that condense in the header are knocked out before the compressor. A compressor suction scrubber protects the machine.
Compression. A low-suction-pressure compressor raises the vapour to the pressure of the gas gathering line, fuel system or flare gas recovery header.
Cooling and separation. Aftercoolers condense heavier components, which are returned to the tanks or a condensate line.
Control. A pressure transmitter on the tank header starts, stops or varies the compressor speed so the tanks never go into vacuum and never lift their relief valves.
Compressor choices
Rotary vane compressors suit small flows and low discharge pressures.
Rotary screw compressors, oil-flooded or dry, handle larger flows and higher pressure ratios.
Liquid ring compressors tolerate liquids and dirty gas and run cool.
Reciprocating compressors suit high discharge pressures where a second stage is needed.
Design points
Vapour rate from flash, working and breathing losses, worked out from the liquid analysis, throughput and climate.
Turndown. Flow can swing widely, so recycle valves or variable speed drives keep the compressor stable.
Oxygen ingress. Tanks that pull in air create a flammable mixture; blanket gas and oxygen analysers prevent it.
Gas composition. Heavy, wet and sometimes sour vapour affects material choice and lubricant selection.
Hazardous area rating of motors, instruments and panels.
Common problems
Tank pressure swings when control is too slow, which lifts the tank vents.
Liquid slugs reaching the compressor when the scrubber is undersized.
Lubricant dilution by heavy hydrocarbons in oil-flooded machines.
Corrosion in sour service where materials were not selected for H2S.
Where Tech Inc. equipment fits
Tech Inc. builds tank vapour recovery units, flare gas recovery units, compressor suction scrubber skids and nitrogen blanketing skids for tank farms. Each unit is sized to the client's tank data and vapour analysis, built in-house and factory-tested.
Related reading
This note is general guidance. Each unit is designed to the project's process data and the applicable codes and standards.





Comments