Data-centre liquid cooling equipment for US operators and integrators: CDUs, coolant treatment and flush-and-fill


Bottom line: Tech Inc. builds the equipment around a data-centre liquid-cooling loop: coolant distribution units (CDUs), side-stream coolant treatment, flush-and-fill rigs, and secondary-loop and chiller skids. US operators and integrators deal with our head office in Vaughan, Ontario, on Eastern Time, from the first quotation to after-sales support.
Why a North American head office matters
Same time zone: our head office is in Vaughan, Ontario, on Eastern Time, so US customers deal with a North American team for quotations, engineering questions and after-sales support.
Our own facilities: engineering and manufacturing are in our own facilities, and every system is proved in a factory acceptance test, with a written report, before it ships. Your own or third-party inspectors are welcome.
Your site, your supply: voltage, frequency and enclosure ratings are taken from your specification at quotation.
Documents with every offer: datasheet, P&ID and 3D model, with drawings submitted for approval before manufacture.
Coolant distribution units
The Coolant Distribution Unit (CDU) for Liquid Cooling transfers heat from the technology cooling loop that serves liquid-cooled servers to the facility water system. A liquid-to-liquid plate exchanger separates the two loops, redundant variable-speed pumps circulate the coolant to the rack manifolds, a fine filter protects the cold plates, and the controller holds the coolant supply temperature above the room dew point. Status, alarms and data go to the building management system by Modbus TCP and SNMP.
TI-CDU-R: in-row, rack-format cabinet in the row it serves.
TI-CDU-F: floor-standing facility CDU serving several rows.
TI-CDU-A: liquid-to-air CDU for rooms without facility water.
Design basis: built to the IT heat load, the coolant and your facility water temperatures; coolant is treated water or water/propylene glycol to the server maker's specification; facility water supply temperatures as set out in the ASHRAE TC 9.9 liquid cooling guidelines; dual power feeds as an option.
Coolant treatment
The Coolant Treatment Skid for Data Centre Liquid Cooling works as a side-stream unit: it continuously draws a small share of the loop flow, filters it and doses inhibitor and glycol before returning it to the loop. It connects through side-stream tie-ins, whatever the make of CDU.
TI-CTS-150: single-loop treatment skid for a cooling loop of up to 2 MW of IT load.
TI-CTS-600: hall-level treatment skid at 600 L/min, serving several loops.
Coolant: water with about 25% propylene glycol (PG25), or to client specification.
Monitoring: inline glycol concentration and turbidity, plus pressure, flow and temperature, with a PLC alarm and data link to the BMS or SCADA. Wetted materials are stainless steel.
Flush-and-fill before start-up
Freshly built cooling pipework carries weld debris, cutting oil and particles that can block cold plates soon after start-up. The Flush-and-Fill Rig for Liquid Cooling Loops (TI-FFR-1500, containerised) circulates clean water through the loop at high flow to carry debris out to its filters, then drains the water and fills the loop with glycol coolant, free of air. It logs flow, filter and turbidity records for each loop for handover, and is used to commission halls before servers are connected, to re-flush loops after modifications or contamination, and for coolant change-out.
Secondary loops, closed-loop cooling and chillers
Heat Transfer and Secondary Loop Skid: separates a plant utility such as cooling, chilled or hot water from a clean secondary loop, with a plate exchanger, duty/standby pumps and a primary control valve. The secondary fluid can be demineralised water, water/glycol or the coolant your equipment needs.
Closed-Loop Cooling Water Skid: duty/duty/standby pumps, a plate exchanger to raw, tower or seawater, an expansion vessel, and a dosing pot and side-stream filter to keep the loop clean.
Process Chiller Skid (Water/Glycol): air- or water-cooled, with a buffer tank and duty/standby pumps; a free-cooling dry-cooler stage saves compressor energy in cold weather.
BESS Coolant Fill, Flush and Filtration Cart: for battery energy storage containers on the same campus; TI-BCF-20, -50 and -100 at about 20, 50 and 100 L/min, for fill, flush, filtration, top-up and leak test.
Immersion cooling
Our published range is built around water and water/glycol cooling loops; we do not list a standard immersion tank. Where an immersion system needs a clean secondary loop between its tank exchanger and the facility water, the Heat Transfer and Secondary Loop Skid is the starting point. Send the tank maker's fluid data and duty, and we will confirm in the quotation what we can supply.
See the full ranges on Utility and Pump Packages, New Energy and Power and Utilities.
What to send us
IT heat load per rack, row or hall, and the number of cooling loops.
Coolant: treated water or water/propylene glycol, with the server or cold-plate maker's specification and filtration requirement.
Facility water supply and return temperatures, or room air conditions for liquid-to-air units.
Redundancy: pump arrangement, and single or dual power feeds.
Site supply: voltage, frequency and phase.
Controls: BMS protocol (Modbus TCP or SNMP) and the signals and alarms you need.
For flush-and-fill: loop pipework sizes and volumes, and the cleanliness acceptance criterion.
Delivery address and required date.
Next step
Send your data to mail@techincresearch.com, call +1 (289) 622-1032 (Eastern Time) or use our enquiry page. How a project works explains each step from enquiry to factory acceptance test, Shipping and export sets out how equipment is delivered, and every order is made under our Terms of Sale.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement.