top of page

ASTM D3700 Explained: Sampling LPG and NGL with a Floating Piston Cylinder

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Liquefied petroleum gas and natural gas liquids are only liquid under pressure. Sample them carelessly and the light components flash into vapour, so the laboratory analyses a different product. ASTM D3700 is the standard practice for sampling them with a floating piston cylinder. The current edition is D3700-26.

What it covers

ASTM's published scope covers equipment and procedures for representative samples of LPG (as specified in ASTM D1835 and GPA 2140), and of other normally single-phase natural gas liquids and volatile crude oils. It does not apply to off-specification products with significant undissolved gases, free water or other separate phases, which need extra precautions. It also notes that some products have too little vapour pressure to move tight piston seals, and points to another practice (D8009) for lower-vapour-pressure liquids.

Why a floating piston

A floating piston cylinder has a piston between the sample and a pre-charge gas, usually nitrogen or helium. As the sample enters, the piston moves against the pre-charge, so the sample stays at or above line pressure, in one liquid phase. Nothing flashes, nothing is vented from the sample side, and the composition the laboratory sees is the composition in the pipe.

Our commentary: practical pitfalls

  • Pre-charge too low. If the pre-charge is below the product's vapour pressure, the sample can flash as it enters.

  • Seal friction and wear. Worn seals let pre-charge gas and sample mix. Track cylinder service history.

  • Temperature. A cylinder warmed in the sun raises internal pressure; respect the relief rating and keep the cylinder shaded.

  • Mixing before analysis. Many cylinders include a mixing ball or stirrer; use it before sub-sampling.

  • Cleaning between samples. Residue from a previous product contaminates trace sulphur and other results.

Tech Inc. equipment

For manual LPG sampling into ordinary cylinders with an outage tube, see the Sample Cylinder Assembly. Related: ASTM D4177 automatic sampling.

Send your line data, product and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments