On a crude export line, an automatic sampler takes thousands of small grabs over a batch and combines them into one sample that decides the water content, density and value of the whole cargo. ASTM D4177 is the standard practice for doing that. The current edition is D4177-22e1.

What it covers

ASTM's published scope describes general procedures and equipment for automatically collecting samples of liquid petroleum, crude oil and intermediate products into a primary container. Its key elements include:

  • the sampling location and probe;

  • mixing of the flowing stream;

  • proportional sampling;

  • the sample extractor's grab volume;

  • control systems and system security.

It also calls for proving the system through performance acceptance tests and ongoing performance monitoring. It excludes electrical insulating oils, hydraulic fluids, and crude sampling below the freezing point of water.

Our commentary: the five things that make or break an automatic sampler

  1. Mixing first. Water and sediment stratify in a pipe. If the stream at the probe is not well mixed, no sampler can take a representative sample. Static mixers, power mixing or a location after pumps and bends solve this.

  2. Probe in the right place. The probe should face the flow near the pipe centre, where the mixed stream is.

  3. Flow-proportional grabs. Each grab must represent the same volume of product, so the grab rate follows the flow meter.

  4. Grab volume repeatability. If grab size drifts, the composite is weighted wrongly.

  5. Receiver handling. The composite must be mixed properly before it is split for the laboratory, or the analysis repeats the stratification problem.

Proving matters as much as hardware

A sampler that has never been proved is an assumption. Performance acceptance testing and ongoing monitoring, such as checking that the collected volume matches the expected number of grabs, are what make the result defensible in a custody dispute.

Tech Inc. equipment for D4177 sampling

Send your line data, product and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.