Reid vapour pressure (RVP) sets gasoline seasonal grades, crude oil storage and shipping limits, and emissions calculations. ASTM D323 is the Reid method. The current edition is D323-26.

What it covers

ASTM's published scope covers vapour pressure at 37.8 °C (100 °F) of gasoline, volatile crude oil and other volatile petroleum products. Procedure A covers gasoline and other products below 180 kPa (26 psi), Procedure C covers higher vapour pressures, Procedure B may also apply, and Procedure D is for aviation gasoline at about 50 kPa (7 psi). It excludes LPG (other methods apply) and fuels with oxygenates other than MTBE, and it notes that precision for crude oil has not been determined since the early 1950s.

Our commentary: the sample decides the number

Vapour pressure is driven by the lightest components: butanes and pentanes. Losing even a little of them between the sample point and the laboratory lowers the result. That makes sampling and handling as important as the test itself:

  • Closed sampling into a cylinder, not an open can.

  • Floating-piston cylinders keep a volatile sample in one phase at line pressure.

  • Fixed-volume cylinders with an outage tube leave controlled vapour space.

  • Keep samples cool and avoid opening containers before the test.

  • No transfers through open air; every transfer loses light ends.

Modern alternatives

Many laboratories now use automated mini-methods for vapour pressure (such as ASTM D5191 for gasoline and D6377 for crude). The sampling rules are the same.