ASME PTC 19.11 Explained: Steam and Water Sampling, Conditioning and Analysis in the Power Cycle

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Boiler chemistry is controlled on samples: feedwater, boiler water, saturated and superheated steam, condensate. ASME PTC 19.11, Steam and Water Sampling, Conditioning, and Analysis in the Power Cycle, is the performance test code that sets how those samples are taken and brought to the analysers. Every steam and water analysis system (SWAS) is built against it.

What it covers

ASME's summary describes the code as covering sampling and conditioning of steam and water in the power cycle, and the analytical methods for the constituents that matter to cycle chemistry: pH, conductivity (specific and cation), dissolved oxygen, sodium, silica, chloride, sulphate, iron, copper, organic carbon and others. It deals with sample nozzle design (isokinetic nozzles for wet and superheated steam), sample lines, primary coolers, pressure reduction, secondary cooling to the analyser temperature, flow and temperature control, and the sequence that protects analysers from upsets.

The design points

  • Isokinetic steam sampling: a nozzle sized so the sample velocity matches the steam velocity, otherwise droplets and solids are over- or under-sampled.

  • Primary cooler: a counter-flow coil cooler sized to bring the sample from steam temperature to near cooling-water temperature; duplex or titanium coils where the cooling water is aggressive.

  • Pressure reduction after cooling, using a rod-in-tube or variable-orifice valve so flashing never occurs upstream of the cooler.

  • Secondary cooling to 25 ± 1 °C, because pH and conductivity readings are temperature-dependent and analyser cells are calibrated at 25 °C.

  • Protection: high-temperature shut-off valves, back-pressure regulators and flow indicators so an upset cannot send hot sample to an analyser.

Our equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.