UTAR and UTP Cast a PVDF and Activated Carbon Membrane for Landfill Leachate

At a glance. Stabilised landfill leachate is one of the hardest wastewaters to treat: old, dark and full of organics that bacteria cannot break down. A team from Universiti Tunku Abdul Rahman and Universiti Teknologi PETRONAS built a PVDF membrane with powdered activated carbon to tackle it, optimised the recipe statistically, and cast every membrane on a Tech Inc. semi-automated membrane casting machine.
Why this matters
As landfills age, their leachate shifts from biodegradable acids to humic substances and ammonia that resist biological treatment. Membranes can remove them, but plain polymer membranes foul quickly and reject only part of the load. Adding an adsorbent such as activated carbon to the membrane itself is an attractive way to raise removal without adding a separate treatment stage.
What the team did
Salahaldin Abuabdou, Zeeshan Haider Jaffari, Choon-Aun Ng, Yeek-Chia Ho and Mohammed Bashir blended powdered activated carbon (PAC) into a PVDF dope and formed thin membranes by phase inversion. They used response surface methodology to find the best combination of PVDF and PAC content, then filtered real stabilised leachate in a cross-flow ring test, measuring COD, colour, ammonia nitrogen, flux and transmembrane pressure.
Where Tech Inc. came in
Response surface methodology only works if the membranes differ in formulation and nothing else. The team cast its membranes on a Tech Inc. semi-automated membrane casting machine, which holds blade gap and casting speed constant from run to run. That consistency is what lets a statistical model separate the effect of 14.9 per cent PVDF from 15 per cent, or 1.0 per cent PAC from 0.5.
Results that stand out
The optimum membrane contained 14.9 wt% PVDF and 1.0 wt% PAC.
It removed 35.34% of COD, 48.71% of colour and 22.00% of ammonia nitrogen from stabilised leachate.
Water flux reached 61.0 L/m²·h at a transmembrane pressure of 0.67 bar.
PAC improved both pollutant removal and permeability compared with plain PVDF.
The authors point to a hydrophilic additive as the next step to raise performance further.
What it means for your lab
Mixed matrix membranes with adsorbents, catalysts or nanoparticles are now standard work in water research, and they need casting that does not drift. Our lab casting machines and roll casting machines cast filled dopes at controlled speed, and we supply the PVDF and NMP to go with them.
The paper
Abuabdou, S. M. A., Jaffari, Z. H., Ng, C.-A., Ho, Y.-C. and Bashir, M. J. K. (2021). A new polyvinylidene fluoride membrane synthesized by integrating of powdered activated carbon for treatment of stabilized leachate. Water 13(16), 2282. doi:10.3390/w13162282
Read the full paper at the publisher for methods, data and figures.
Part of the Research with Tech Inc. series
This post is one of a series on published research made with Tech Inc. equipment and materials. See the full list on Research using Tech Inc. equipment. Next in the series: VIT Casts Supercapacitor Films from Graphene Ink on a Tech Inc. Casting Machine.
Published with our equipment? Send the reference to mail@techincresearch.com and we will feature your work. To discuss equipment for a similar study, call +1 (289) 622-1032 or write to mail@techincresearch.com.





Comments