top of page

Process Note: Turbine Lube Oil Systems and Oil Cleanliness

Writer: Tech Inc
Tech Inc
8 hours ago
2 min read

At a glance. Steam turbines, gas turbines and large compressors rely on a lube oil system to feed cool, clean oil to their bearings, and often to supply control oil and seal oil too. The oil may stay in service for many years, so contamination control decides how long both the oil and the machine last. Power plants, refineries and gas compression stations across the world specify these systems to API 614 and the machine makers' requirements.

The system

  1. Reservoir, sized so that air and water can separate, often with a heater and a vapour extractor.

  2. Pumps: a main pump, shaft-driven or motor-driven; an AC auxiliary pump that starts on low pressure; and a DC emergency pump or rundown tank to protect the bearings during a coast-down after power loss.

  3. Coolers, usually twin, with a temperature control valve.

  4. Duplex filters with a transfer valve, so that elements can be changed while the machine runs.

  5. Pressure control to the bearing header, with relief and back-pressure valves.

  6. Return by gravity to the reservoir.

  7. Oil conditioning on a side stream: centrifuges, vacuum dehydrators, coalescers or varnish-removal units.

What is monitored

  • Particle cleanliness to ISO 4406, against the target the machine maker or plant sets.

  • Water content, as free and dissolved water speed wear, oxidation and corrosion.

  • Oxidation and remaining antioxidant, by oil analysis.

  • Varnish potential, for example by membrane patch colorimetry to ASTM D7843, especially in gas turbines.

  • Filter differential pressure, oil temperatures and pressures at the console.

ASTM D4378 gives guidance on in-service monitoring of turbine oils.

Design points

  • Reliability of supply: pump redundancy, automatic changeover and protection on loss of power.

  • Filtration rating matched to bearing and servo valve clearances.

  • Reservoir residence time for releasing air and water.

  • Pipework materials and cleanliness, with stainless steel common downstream of the filters.

  • Flushing of new or repaired systems before start-up, with guidance in ASTM D6439.

  • Breathers that keep moisture and dust out of the reservoir.

Common problems

  • Water ingress from steam gland leaks, cooler leaks or condensation.

  • Varnish that sticks servo valves and raises bearing temperatures.

  • Filters in bypass because elements were not changed on differential pressure.

  • Contamination during top-ups from dirty drums and transfer containers.

  • Foaming and air entrainment from low oil level or contamination.

Where Tech Inc. equipment fits

Related reading

This note is general guidance. Oil cleanliness targets and system design follow the machine maker's requirements and the plant's own standards.

Comments