Separation and Produced Water Packages Compared: Capacity, Pressure and Outlet Quality


Bottom line: for continuous production, the two- and three-phase production separator runs from about 24 to 72 inch diameter; for well tests, the test separator package separates and meters oil, gas and water up to Class 600. Sand at the wellhead needs the wellhead desander, rated to 10,000 psi. For produced water, the treatment package combines hydrocyclone, flotation and walnut shell stages from about 5,000 to 100,000 bbl/d.
The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.
Well and production separation
Product | Models | Capacity | Pressure | Performance | Design and materials |
|---|---|---|---|---|---|
TI-PSP-24 to TI-PSP-72; about 24 to 72 inch diameter | sized to the flow and the fluids | about 10 to 100 barg (145 to 1,450 psig), by service | two- or three-phase; horizontal or vertical | ASME VIII Div. 1, sizing to API 12J; NACE MR0175 / ISO 15156 where required; carbon steel, duplex or clad | |
TI-TSP-600 to TI-TSP-1500; vessel about 600 to 1,500 mm | set by the well flow rates and fluids | up to Class 600 | separates and meters oil, gas and water; orifice or ultrasonic gas meter; Coriolis or turbine liquid meters | ASME VIII and API 12J | |
TI-WDS-3K, 5K and 10K | flow and sand load sized to the well | to 3,000, 5,000 or 10,000 psi | cyclone liner life typically 6–24 months, depending on sand load and flow | ASME VIII / API 6A; NACE MR0175 / ISO 15156; tungsten carbide or ceramic liner | |
TI-MGS-750, 900 and 1200; vessel about 750 to 1,200 mm | from drilling or well-test flow rates | – | removes gas from mud and sand from well streams; vent to a safe location or flare | ASME VIII; skid or trailer mounted | |
TI-MCG-400 to TI-MCG-1200; DN 400 to 1,200 | cyclone count set by the gas flow | to client specification | liquid and dust removal without elements | ASME VIII; carbon steel, low-temperature carbon steel or stainless | |
TI-DSL-2 to TI-DSL-60 | about 2,000 to 60,000 bbl/d of crude | – | outlet salt typically below 10 PTB | electrostatic vessel with transformer; one or two stages | |
modules selected to suit the field | sized to the field's oil, gas and water production | – | produced water treated to the client's injection or disposal limit | three-phase separator, heater-treater, gas handling and flare; PLC and SCADA control room |
Produced water treatment
Product | Models | Capacity | Pressure | Outlet quality | Design and materials |
|---|---|---|---|---|---|
TI-PWT-5 to TI-PWT-100 | about 5,000 to 100,000 bbl/d | – | oil-in-water typically below 40 mg/l for disposal, below 10 mg/l for injection | hydrocyclone, gas flotation and walnut shell filter stages on skids | |
liner count chosen for design flow and turndown | sized to the duty | driving pressure from the upstream separator or a booster pump | to suit the downstream flotation, filtration or injection specification | ASME VIII; carbon steel or duplex vessels with corrosion-resistant liners | |
TI-IGF-50 | typically 50,000 bbl/d per unit | – | to suit the downstream filter or the injection specification | ASME VIII; coated carbon steel or stainless; produced gas, fuel gas or nitrogen as flotation gas | |
TI-NSF100 train | typically 100,000 bbl/d per train (about 662 m³/h) | to client specification | to the project's injection or disposal specification | ASME VIII; lined or coated carbon steel; scrubbing and backwash cleaning | |
TI-PF100 | typically 100,000 bbl/d per skid (about 662 m³/h) | to client specification | two stages; element ratings selected for the injection water specification | ASME VIII; coated carbon steel, stainless or duplex; standby housing for element change |
How to choose
Start from the fluids: oil, gas and water rates, sand and H2S content set the vessel size, internals and materials.
Rate for the worst case: wellhead equipment sees shut-in pressure, while plant separators see the upstream relief setting.
For produced water, fix the outlet target first: disposal and injection limits decide how many treatment stages you need.
Sour service needs materials to NACE MR0175 / ISO 15156 from the start, not as a later change.
Allow for change: well rates, water cut and sand load usually change over the life of the field.
All models: separation and produced water range.
Before you order
Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.