Application Note: Recovering Acetone, IPA, Methanol and Other Solvents in Pharma Plants

At a glance. Active pharmaceutical ingredient plants use solvents for reactions, extractions, crystallisation and cleaning, often in volumes far larger than the product. Recovering them cuts cost and hazardous waste, but each solvent behaves differently in distillation, and reuse inside a regulated process has to be justified.
How common solvents behave
Acetone and methanol boil low and separate readily from heavy residues; simple or fractional distillation gives a good product.
Isopropanol and ethanol form azeotropes with water, so distillation stops short of dry solvent. A drying step such as molecular sieves or pervaporation is needed when dry solvent is required.
Toluene and other hydrocarbons separate from water as a second liquid layer, which helps recovery.
Chlorinated solvents such as dichloromethane boil very low, need good condensing and are checked for acid formation.
The recovery step
Collect and segregate. Keep solvent streams apart by type; mixed streams are harder to recover.
Distil. A batch still or a fractionation column separates the solvent from residues, water and other solvents.
Dry if needed. Molecular sieves or pervaporation membranes take the solvent past its azeotrope.
Test. Purity, water content and impurities are checked against the specification for reuse.
Reuse
Recovered solvent is often reused in the same process step, in earlier steps, for cleaning, or sold, depending on the plant's quality system and validation. The equipment should keep records that support that decision.
Where Tech Inc. equipment fits
Tech Inc. builds the spent solvent recycling still, the falling-film solvent recovery skid, industrial rotary evaporators and pervaporation test systems for solvent drying, and the nitrogen blanketing skid for solvent tanks.
Related reading
Sources
ICH Q7, Good Manufacturing Practice for Active Pharmaceutical Ingredients – ICH, published by the European Medicines Agency
ICH Q3C (R8), Impurities: Guideline for Residual Solvents – ICH, published by the European Medicines Agency
This note is general information. Reuse of recovered solvent follows the plant's quality system and regulatory requirements.





Comments