Osmotic Pressure Calculation for RO Feed Water: The van 't Hoff Equation with Worked Examples

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Reverse osmosis has to push water against the osmotic pressure of the feed. Knowing that pressure tells you the minimum feed pressure, why seawater RO needs so much more pressure than brackish RO, and how quickly pressure demand rises with recovery.

The equation

For dilute solutions, the van 't Hoff equation gives:

Π = i × M × R × T

  • Π: osmotic pressure.

  • i: van 't Hoff factor, the number of ions per formula unit (2 for sodium chloride).

  • M: molar concentration in mol/L.

  • R: gas constant, 0.08314 L·bar/(mol·K) (or 0.0821 L·atm/(mol·K)).

  • T: temperature in kelvin.

Worked example 1: brackish test solution

2,000 mg/L sodium chloride at 25 °C (298.15 K):

  • M = 2.0 g/L ÷ 58.44 g/mol = 0.0342 mol/L

  • Π = 2 × 0.0342 × 0.08314 × 298.15 = 1.70 bar

Worked example 2: seawater-strength salt

35,000 mg/L sodium chloride at 25 °C:

  • M = 35 ÷ 58.44 = 0.599 mol/L

  • Π = 2 × 0.599 × 0.08314 × 298.15 = 29.7 bar

The equation assumes ideal behaviour, so at seawater strength it is an estimate; real solutions deviate as concentration rises. It is still the right order of magnitude, and it explains why seawater RO runs at far higher pressures than brackish RO.

Recovery raises the pressure needed

As water passes through the membrane, the concentrate gets saltier. At 50% recovery with near-full rejection, the concentrate is about twice the feed concentration, so its osmotic pressure is roughly doubled. The tail end of the system needs enough pressure to overcome that. See recovery and concentration factor calculations.

Using it in testing

  • Net driving pressure is feed pressure minus osmotic pressure difference (and losses), so flux comparisons must account for it. See normalised permeate flow.

  • In forward osmosis, the draw solution's osmotic pressure is the driving force; the same equation applies.

Our lab-scale RO test skids and high-pressure multi-cell systems are built for brackish and seawater test pressures. See also the salt rejection guide.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Worked examples use illustrative numbers. Equipment specifications are typical and may change; results depend on the membranes and conditions tested, how the equipment is used and operation in line with the operation manual.