top of page

Application Note: Keeping Diesel Clean at Mine Sites and Power Plants

Writer: Tech Inc
Tech Inc
5 days ago
2 min read

At a glance. Haul trucks, shovels, drills and diesel generators use common-rail injection at very high pressure, with clearances of a few microns. Dirt and water in the fuel wear injectors and pumps quickly. Mine sites and remote plants receive fuel by road, store it in tanks that breathe humid air and dispense it in dusty conditions, so the fuel is often far dirtier than the engines can tolerate.

Where contamination comes from

  • Delivery. Fuel picks up particles and water in the supply chain and the tanker.

  • Storage. Tanks breathe in moist air, water condenses and settles, and microbes grow at the fuel–water interface.

  • Handling. Open hatches, dirty nozzles and hoses add dust at the dispenser.

Cleanliness targets

Particle contamination is reported as an ISO 4406 code, three numbers that count particles larger than 4, 6 and 14 µm per millilitre. The Worldwide Fuel Charter recommends 18/16/13 for diesel as delivered to the user, and some engine makers ask for cleaner fuel still. Water should be kept to a few hundred ppm or less.

Where to filter

  1. On receipt. Filter fuel as it enters storage, so dirt never reaches the tank.

  2. In storage. Circulate tanks through a kidney-loop polishing skid with a water coalescer and fine filters, and drain water from tank bottoms.

  3. At the dispenser. A final filter and water separator protects the machine's own filters.

  4. Keep air out. Desiccant breathers on tank vents stop moist air and dust coming in.

Measuring progress

Differential-pressure gauges show when elements need changing, and an online particle and water sensor, or regular samples, show whether the fuel meets the target code.

Where Tech Inc. equipment fits

Related reading

Sources

This note is general information. Cleanliness targets come from the engine maker's fuel specification.