top of page

Testing Valves, Fittings and Hoses for Hydrogen Service

Writer: Tech Inc
Tech Inc
5 days ago
2 min read

At a glance. Valves, fittings, hoses and cylinders for hydrogen stations and vehicles are tested for leaks, proof and burst pressure and for thousands of pressure cycles, often at low and high temperature. Many tests use hydrogen itself, because hydrogen leaks through joints that hold nitrogen and can embrittle susceptible steels. A hydrogen test stand needs a gas booster, a bunkered test chamber, gas detection and venting, and software that records every step.

The usual tests

  • Leak tests – at low and full pressure, with helium or hydrogen and a sensitive detector.

  • Proof tests – a pressure above the rating held for a set time.

  • Burst tests – hydraulic, to failure, in a bunker.

  • Pressure cycling – thousands of cycles between low and full pressure, at the temperatures the standard sets.

  • Material tests – steels for hydrogen service may be qualified by methods such as those in ISO 11114-4.

Which standards

Component standards set the tests and limits: ISO 19880-3 for valves in fuelling stations and ISO 19880-5 for dispenser hoses and hose assemblies, among others. The stand is built so that its sequences follow the standard the client names.

What the stand includes

  1. A hydrogen and helium booster to the test pressure, often 875 bar or more for 70 MPa systems.

  2. A bunker with an interlocked door, blow-out venting and gas detection.

  3. A hydraulic circuit for burst tests.

  4. A temperature chamber where cycling at low and high temperature is required.

  5. Software for sequences, limits and test reports.

Safety

Hydrogen detection, ventilation, flame-free electrical design in the test area and venting to a safe height are part of the design, not options.

Where Tech Inc. equipment fits

Related reading

Sources

This guide is general information. Test programmes follow the component standard and the certifying body's requirements.