Hydraulic Power and Test Units Compared: Pressure, Flow, Medium and Standards

Writer: Tech Inc
Tech Inc
6 hours ago
5 min read
Hydraulic Power and Test Units Compared: Pressure, Flow, Medium and Standards

Bottom line: for hydraulic actuation, the hydraulic power unit gives up to 10,000 psi with duty and standby pumps; well control needs the BOP accumulator unit or the workover control unit. Field pressure tests suit the hydrotest pump skid, to about 1,000 bar (14,500 psi), or the hydrostatic test unit, to 20,000 psi as standard. Burst, leak, cycling, calibration and filter test benches are in the second table.


The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.


Power units, control units and field test skids

Product

Models

Pressure

Flow or capacity

Medium

Drive

TI-HPU-3K, 5K and 10K

up to 10,000 psi; higher with intensifiers

to the application

cleanliness to the ISO 4406 target; SS316L reservoir

electric (Ex d) or pneumatic

TI-HHT-10K, 20K and 30K (on request)

up to 20,000 psi standard; higher on request

–

water or hydraulic oil

drive air at 6 to 7 bar (87 to 102 psi); digital data logger

TI-HTP-250, 450, 700, 1000 and F

to about 1,000 bar (14,500 psi) by model

about 5 to 60 L/min test pump; fill pump to about 1,000 L/min

–

electric motor, diesel engine or compressed air

TI-GBU-3K, 6K and 10K

up to 10,000 psi typical

–

nitrogen, helium or air

compressed air

TI-NCC-200-2 to TI-NCC-350-T

up to about 350 bar (5,080 psi), adjustable

two to six cylinders, or a trailer bank

dry, oil-free nitrogen

air-driven booster (none on the TI-NCC-200-2); electric on request

TI-BOP-80 to TI-BOP-320

accumulator typically 3,000 psi; control manifold up to 5,000 psi

about 80 to 320 US gal accumulator

–

electric and air-driven pumps; API 16D

TI-WCU-5, 10, 15 and A

to about 345, 690 or 1,035 bar (5,000, 10,000 or 15,000 psi)

two to eight valve functions

–

air-driven or electric pumps

replacement module for the existing unit

matched to the existing duty

matched to the existing duty

turbine oil or fire-resistant fluid

–

TI-HFU-50 to TI-HFU-600

–

about 50 to 600 L/min

hydraulic oil; filtration down to 3 µm absolute

electric or diesel

TI-OFS-200 to TI-OFS-4000

–

about 200 to 4,000 L/min

lube, seal or hydraulic oil up to about 70 °C (158 °F)

electric with variable-speed drive; diesel on request

TI-CCS-1 to TI-CCS-10

–

about 30 to 200 m³/h; tank about 1 to 10 m³

degreasers, inhibited acids, citric acid, neutralisers and passivating solutions, to about 80 °C (176 °F)

–

TI-RPT-300, 400, PL and M

to about 300 or 400 bar (4,350 or 5,800 psi)

–

helium, nitrogen and air

remote control from a control room


Test benches and laboratory test systems

Product

Models

Pressure

Range or test

Medium

Standards

TI-SVT-8, 16 and 24

to client specification

valves from 1/2 inch to 8, 16 or 24 inch; set pressure, shell and seat

water, nitrogen or air

API 598 and API 6D

TI-BPT-2000

up to about 2000 bar (30,000 psi)

programmable ramp about 0.1 to 50 bar (1 to 725 psi)/s

water, oil or water-glycol

ISO 1402, ISO 6605 and SAE J343 methods

TI-BBT-100

up to about 50 bar (725 psi) gas; higher with hydraulic option

vent pressure, burst pressure, pass/fail

gas, or hydraulic option

–

TI-PDL-100

vacuum to about 20 bar (290 psi)

resolution about 0.1 Pa; cycle typically 5 to 30 seconds

–

–

TI-HPH-1000

up to about 1000 bar (15,000 psi)

pressure and temperature recorded; certificate output

water or hydraulic oil

–

TI-APC-100

vacuum to about 200 bar (2,900 psi)

typically ±0.05% of full scale; set point, ramp, hold and cyclic profiles

air, nitrogen, helium and inert gases

–

TI-AHC-700

up to about 700 bar (10,200 psi)

closed-loop set point, ramp and cycle

mineral or synthetic hydraulic oil

–

TI-CPT-500

peak up to about 1000 bar (14,500 psi)

about 0.1 to 2 Hz; oil up to about 120 °C (248 °F)

oil

ISO 6803, ISO 10771-1 and SAE J343 methods

TI-PGC-700

vacuum to about 1000 bar (14,500 psi), by model

reference typically ±0.025% of full scale

–

–

TI-HTS-450, 875, 1000 and B

gas to about 1,000 bar (14,500 psi); hydraulic burst to about 4,000 bar (58,000 psi)

leak, proof, burst and cycling; about -40 to +85 °C (−40 to 185 °F) conditioning on request

hydrogen or helium

–

TI-HCT-60, 150, 300 and HP

to about 420 bar (6,090 psi); to about 1,000 bar (14,500 psi) for proof tests

about 1 to 300 L/min

mineral and synthetic hydraulic oils

–

TI-CRQ-15, 50, 80 and L

to about 450 bar (6,530 psi)

steel, aluminium and composite cylinders up to about 80 L

water-jacket or direct expansion

ISO 18119, ISO 11623 and CGA C-1

TI-HCB-400, 1000, 1500 and XL

to about 1,500 bar (21,800 psi) by model

cylinders up to about 150 L; XL chamber for tubes and tanks up to about 6 m

water

to the cylinder standard the client works to

TI-MPT-H, L, F and C

–

test loops from 50 L/h (fuel filters) to 600 L/min (lube oil filters) across the standards

test fluid as the standard specifies; ISO medium test dust

ISO 16889, ISO 23369, ISO 4548-12 and ISO 19438

TI-FCB-S, L and E

differential pressure range chosen to the highest rating tested

collapse/burst pressure and end load

mineral hydraulic oil or the specified fluid

ISO 2941, ISO 3723 and ISO 2942

TI-FFR-E, P and C

cycles between upper and lower set values

cycle rate set by the volume of the part tested

mineral hydraulic oil or the specified fluid

ISO 3724 and ISO 10771-1

TI-FDP-L, M and H

–

pump sized to the largest filter tested

mineral hydraulic oil or the specified fluid

ISO 3968

TI-RTL-150, 300, 350 and C

to about 20, 150 or 200 bar, by model

to about 150, 300 or 350 °C; flow to about 2 to 5 m³/h

high-temperature water or steam

ASME B31.3 and ASME VIII


How to choose

  • Rate for the test, not the working pressure: test pressures sit above design pressure, so check the code you test to.

  • Choose the medium: water for hydrotests, oil for hydraulic components, and gas only where the test needs it, with the extra safety measures gas testing requires.

  • Match the drive to the site: air-driven pumps need no electrical power in hazardous areas, while electric and diesel drives give more flow.

  • Keep records: data loggers and printed certificates make every test traceable for the client and the inspector.

  • Mind cleanliness: hydraulic systems and test benches need filtration to the ISO 4406 class the components require.


Not ready to buy? Our burst and pressure testing service runs recorded burst, proof and leak tests for you. All models: hydraulic power and test units range.


Before you order

Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.


Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.