Hydraulic Power and Test Units Compared: Pressure, Flow, Medium and Standards


Bottom line: for hydraulic actuation, the hydraulic power unit gives up to 10,000 psi with duty and standby pumps; well control needs the BOP accumulator unit or the workover control unit. Field pressure tests suit the hydrotest pump skid, to about 1,000 bar (14,500 psi), or the hydrostatic test unit, to 20,000 psi as standard. Burst, leak, cycling, calibration and filter test benches are in the second table.
The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.
Power units, control units and field test skids
Product | Models | Pressure | Flow or capacity | Medium | Drive |
|---|---|---|---|---|---|
TI-HPU-3K, 5K and 10K | up to 10,000 psi; higher with intensifiers | to the application | cleanliness to the ISO 4406 target; SS316L reservoir | electric (Ex d) or pneumatic | |
TI-HHT-10K, 20K and 30K (on request) | up to 20,000 psi standard; higher on request | – | water or hydraulic oil | drive air at 6 to 7 bar (87 to 102 psi); digital data logger | |
TI-HTP-250, 450, 700, 1000 and F | to about 1,000 bar (14,500 psi) by model | about 5 to 60 L/min test pump; fill pump to about 1,000 L/min | – | electric motor, diesel engine or compressed air | |
TI-GBU-3K, 6K and 10K | up to 10,000 psi typical | – | nitrogen, helium or air | compressed air | |
TI-NCC-200-2 to TI-NCC-350-T | up to about 350 bar (5,080 psi), adjustable | two to six cylinders, or a trailer bank | dry, oil-free nitrogen | air-driven booster (none on the TI-NCC-200-2); electric on request | |
TI-BOP-80 to TI-BOP-320 | accumulator typically 3,000 psi; control manifold up to 5,000 psi | about 80 to 320 US gal accumulator | – | electric and air-driven pumps; API 16D | |
TI-WCU-5, 10, 15 and A | to about 345, 690 or 1,035 bar (5,000, 10,000 or 15,000 psi) | two to eight valve functions | – | air-driven or electric pumps | |
replacement module for the existing unit | matched to the existing duty | matched to the existing duty | turbine oil or fire-resistant fluid | – | |
TI-HFU-50 to TI-HFU-600 | – | about 50 to 600 L/min | hydraulic oil; filtration down to 3 µm absolute | electric or diesel | |
TI-OFS-200 to TI-OFS-4000 | – | about 200 to 4,000 L/min | lube, seal or hydraulic oil up to about 70 °C (158 °F) | electric with variable-speed drive; diesel on request | |
TI-CCS-1 to TI-CCS-10 | – | about 30 to 200 m³/h; tank about 1 to 10 m³ | degreasers, inhibited acids, citric acid, neutralisers and passivating solutions, to about 80 °C (176 °F) | – | |
TI-RPT-300, 400, PL and M | to about 300 or 400 bar (4,350 or 5,800 psi) | – | helium, nitrogen and air | remote control from a control room |
Test benches and laboratory test systems
Product | Models | Pressure | Range or test | Medium | Standards |
|---|---|---|---|---|---|
TI-SVT-8, 16 and 24 | to client specification | valves from 1/2 inch to 8, 16 or 24 inch; set pressure, shell and seat | water, nitrogen or air | API 598 and API 6D | |
TI-BPT-2000 | up to about 2000 bar (30,000 psi) | programmable ramp about 0.1 to 50 bar (1 to 725 psi)/s | water, oil or water-glycol | ISO 1402, ISO 6605 and SAE J343 methods | |
TI-BBT-100 | up to about 50 bar (725 psi) gas; higher with hydraulic option | vent pressure, burst pressure, pass/fail | gas, or hydraulic option | – | |
TI-PDL-100 | vacuum to about 20 bar (290 psi) | resolution about 0.1 Pa; cycle typically 5 to 30 seconds | – | – | |
TI-HPH-1000 | up to about 1000 bar (15,000 psi) | pressure and temperature recorded; certificate output | water or hydraulic oil | – | |
TI-APC-100 | vacuum to about 200 bar (2,900 psi) | typically ±0.05% of full scale; set point, ramp, hold and cyclic profiles | air, nitrogen, helium and inert gases | – | |
TI-AHC-700 | up to about 700 bar (10,200 psi) | closed-loop set point, ramp and cycle | mineral or synthetic hydraulic oil | – | |
TI-CPT-500 | peak up to about 1000 bar (14,500 psi) | about 0.1 to 2 Hz; oil up to about 120 °C (248 °F) | oil | ISO 6803, ISO 10771-1 and SAE J343 methods | |
TI-PGC-700 | vacuum to about 1000 bar (14,500 psi), by model | reference typically ±0.025% of full scale | – | – | |
TI-HTS-450, 875, 1000 and B | gas to about 1,000 bar (14,500 psi); hydraulic burst to about 4,000 bar (58,000 psi) | leak, proof, burst and cycling; about -40 to +85 °C (−40 to 185 °F) conditioning on request | hydrogen or helium | – | |
TI-HCT-60, 150, 300 and HP | to about 420 bar (6,090 psi); to about 1,000 bar (14,500 psi) for proof tests | about 1 to 300 L/min | mineral and synthetic hydraulic oils | – | |
TI-CRQ-15, 50, 80 and L | to about 450 bar (6,530 psi) | steel, aluminium and composite cylinders up to about 80 L | water-jacket or direct expansion | ISO 18119, ISO 11623 and CGA C-1 | |
TI-HCB-400, 1000, 1500 and XL | to about 1,500 bar (21,800 psi) by model | cylinders up to about 150 L; XL chamber for tubes and tanks up to about 6 m | water | to the cylinder standard the client works to | |
TI-MPT-H, L, F and C | – | test loops from 50 L/h (fuel filters) to 600 L/min (lube oil filters) across the standards | test fluid as the standard specifies; ISO medium test dust | ISO 16889, ISO 23369, ISO 4548-12 and ISO 19438 | |
TI-FCB-S, L and E | differential pressure range chosen to the highest rating tested | collapse/burst pressure and end load | mineral hydraulic oil or the specified fluid | ISO 2941, ISO 3723 and ISO 2942 | |
TI-FFR-E, P and C | cycles between upper and lower set values | cycle rate set by the volume of the part tested | mineral hydraulic oil or the specified fluid | ISO 3724 and ISO 10771-1 | |
TI-FDP-L, M and H | – | pump sized to the largest filter tested | mineral hydraulic oil or the specified fluid | ISO 3968 | |
TI-RTL-150, 300, 350 and C | to about 20, 150 or 200 bar, by model | to about 150, 300 or 350 °C; flow to about 2 to 5 m³/h | high-temperature water or steam | ASME B31.3 and ASME VIII |
How to choose
Rate for the test, not the working pressure: test pressures sit above design pressure, so check the code you test to.
Choose the medium: water for hydrotests, oil for hydraulic components, and gas only where the test needs it, with the extra safety measures gas testing requires.
Match the drive to the site: air-driven pumps need no electrical power in hazardous areas, while electric and diesel drives give more flow.
Keep records: data loggers and printed certificates make every test traceable for the client and the inspector.
Mind cleanliness: hydraulic systems and test benches need filtration to the ISO 4406 class the components require.
Not ready to buy? Our burst and pressure testing service runs recorded burst, proof and leak tests for you. All models: hydraulic power and test units range.
Before you order
Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.