High-Pressure Gas Systems Compared: Pressure, Gases, Flow and Standards


Bottom line: for helium and nitrogen at up to 400 bar (5,800 psi), the storage and distribution skid, mobile servicing rig and pressurisation, purge and command-gas panel cover storage, mobile servicing and distribution to each circuit. Laboratories and plants that draw gas from cylinders need a changeover manifold, gas panel or distribution system. Process duties such as blanketing, purge and recovery have their own skids below.
Storage, servicing and test systems
System | Gases | Pressure | Capacity or flow | Control and features | Codes and standards |
|---|---|---|---|---|---|
helium or nitrogen | storage up to 400 bar (5,800 psi) | 24 cylinders per skid | local gauges, or transmitters and remote valves | – | |
helium or nitrogen | up to 400 bar (5,800 psi) | to client specification | charging, pressure testing, purging; manual or PLC | – | |
helium or nitrogen | inlet up to 400 bar (5,800 psi) | circuits to client specification | solenoid valves with manual isolation; PLC or hard-wired | – | |
helium and nitrogen | up to 400 bar (5,800 psi) | sized to test duration and runs | PLC with interlocks; storage, boosting, panels and piping | – | |
helium, nitrogen, air | to about 300 or 400 bar (4,350 or 5,800 psi) | – | remote control with interlocks; data logged | ASME B31.3 practice | |
dry, oil-free nitrogen | up to about 350 bar (5,080 psi) | 2 to 6 cylinders, or trailer bank | air-driven or electric booster | ASME B31.3 practice | |
hydrogen or helium | gas to about 1,000 bar (14,500 psi); hydraulic burst to about 4,000 bar (58,000 psi) | – | programmable cycling; −40 to +85 °C conditioning on request | ISO 19880-3, ISO 19880-5, ISO 12619 | |
– | to about 450 bar (6,530 psi) | cylinders up to about 80 L | expansion by burette or weighing; records and certificates | ISO 18119, ISO 11623, CGA C-1 | |
– | – | tube about 1/8 to 1 inch | orbital TIG; helium leak test; weld records | ASME B31.3 practice |
Gas supply, distribution and pressure control
System | Gases | Pressure | Capacity or flow | Control and features | Codes and standards |
|---|---|---|---|---|---|
hydrogen and industrial gases | inlet up to 200 bar (2,900 psi) | about 25 to 600 Nm³/h | wall panel or skid; SS316 | client's gas safety specification | |
inert, flammable, oxidising and specialty | inlet to about 200 or 300 bar (2,900 or 4,350 psi); outlet about 0 to 10 barg (0 to 145 psig) | two cylinders or two banks | differential or electronic switching; alarms | ASME B31.3 practice; ASTM G93 | |
laboratory and process gases | inlet to about 300 bar (4,350 psi); distribution about 5 to 15 barg (73 to 218 psig) | laid out to the building | 316L tube; gas detection and shut-off | ASME B31.3 | |
CO2, nitrogen, argon, helium, hydrogen, air, mixtures | inlet 200 or 300 bar (2,900 or 4,350 psi); outlet typically 1 to 10 barg (15 to 145 psig) | 1 to 4 gases | changeover and low-pressure alarms | ASME B31.3 | |
oxygen | inlet to about 200 bar (2,900 psi) | – | slow-opening valves; oxygen-compatible seals | ASTM G93; ASME B31.3 practice | |
He, N2, Ar, H2, specialty | fill 200 or 300 bar (2,900 or 4,350 psi) | 6, 12 or 24 filling points | fill controller with temperature compensation | ASME B31.3 | |
air, N2, He, inert gases | vacuum to about 200 bar (2,900 psi) | – | ramp, hold and cyclic profiles; ±0.05% FS typical | – | |
– | up to about 700 bar (10,000 psi) | µL/min to pilot scale | to about 200 °C (392 °F) by seat; 1/16 to 1/2 inch fittings | – | |
hydrogen | inlet 200 or 300 bar (2,900 or 4,350 psi) | fuel cells to about 100 kW | excess-flow valves; detection; alarms | ASME B31.12 | |
non-reactive and reactive | vacuum to about 10⁻³ mbar | cylinders up to about 50 L | electropolished 316L, helium leak-tested | ISO 6142-1; ISO 6143 | |
breathing air | storage 300 bar (4,350 psi) | about 60 to 240 m³ free air | fill enclosure; slow-fill restrictors | EN 12021; ASME B31.3 practice | |
breathing air | 50 L, 300-bar cylinders | up to 12 workers | automatic bank changeover; alarms | EN 12021 |
Process and industry gas skids
System | Gases | Pressure | Capacity or flow | Control and features | Codes and standards |
|---|---|---|---|---|---|
nitrogen or CO2 | matched to the gasifier | about 100 to 1,500 Nm³/h | boosters; PLC sequence control | pressure vessel code or client specification | |
nitrogen | low pressure, set to the tank | about 25 to 300 Nm³/h | skid, wall panel or tank-top | – | |
hydrogen; nitrogen purge | – | – | back-pulse filter candles; PLC purge sequences | ASME VIII or client specification | |
air, O2, N2, CO2 | – | vessels about 5 to 5,000 L | thermal mass flow controllers; SS316L | – | |
aqueous or anhydrous ammonia | – | about 5 to 200 kg/h ammonia | PLC with NOx trim; ammonia detection | ASME B31.3; IEC 60079 | |
nitrogen with hydrogen | – | about 500 to 6,000 Nm³/h | up to about 20 zones; PLC, HMI, DCS link | ASME B31.3; IEC 60079 | |
HFCs, HFOs and blends | to about 30 barg (435 psig) | about 50 to 400 kg/h | automatic purge of non-condensables | ASME VIII, ASME B31.3; AHRI 700 | |
helium | storage about 150 to 300 bar (2,180 to 4,350 psi) | about 5 to 100 Nm³/h | purity typically 99.99% or better; analysers; PLC | ASME VIII, ASME B31.3 | |
oxygen | cones to about 3 barg (44 psig) | about 10 to 400 kg O2 per day | dissolved-oxygen control; super duplex 2507 or 316L | – | |
SF6; alternative mixtures | filling to about 10 bar (145 psi); vacuum to about 1 mbar | scale to about 100 kg, about 10 g resolution | DN8 and DN20 self-sealing couplings | IEC 62271-4 | |
liquid nitrogen | – | about 5 to 200 L/day | nitrogen about 99.5% or better; automatic start-stop | IEC 61010; ASME B31.3 practice | |
hydrogen (PEM) | generator about 16 bar (232 psi); booster about 100 bar (1,450 psi) | about 0.5 to 1 L/min | leak detection, relief, flame arrestor, shut-down | IEC 61010-1; ASME B31.3 practice |
How to choose
Start from the highest pressure anywhere in the system, including boosters and cylinder banks, not the use pressure.
Gas decides materials and cleaning: oxygen needs oxygen-clean parts; hydrogen needs suitable materials, detection and venting.
Hazardous areas: give us the area classification so electrical components are selected to it.
Cylinder supply or recovery: count the cylinders or flow you use each day before choosing manual, automatic or bulk supply.
Ask for the design code and test records you need at the enquiry stage.
All models: high-pressure gas systems.
Before you order
Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.