top of page

The Tech Inc. Ammonia Vaporiser and SCR Injection Skid supplies the ammonia that a selective catalytic reduction (SCR) system needs to turn NOx into nitrogen and water. Aqueous or anhydrous ammonia is metered, vaporised with heated dilution air or an electric vaporiser, mixed and distributed through an injection grid ahead of the catalyst, with the flow trimmed to the NOx measured at the stack.

At a glance: about 5 to 200 kg/h ammonia · aqueous or anhydrous · heated-air or electric vaporiser · PLC trim from NOx analyser · ammonia detection and shut-off

Download the datasheet (PDF)

 

Main components

  • Ammonia metering pumps or flow-control valves
  • Vaporiser: heated dilution air or electric vaporiser
  • Dilution-air blowers and heater
  • Mixing chamber and flow distribution to the injection grid
  • Ammonia detection and safety shut-off
  • PLC linked to the NOx analyser

 

Applications: gas-turbine and combined-cycle plants, boilers, refinery fired heaters and other plants that must cut NOx emissions with SCR.

 

Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.