Setting Up an In-House HIC and SSC Test Laboratory

At a glance. Steels for sour service are qualified by laboratory tests in hydrogen sulphide: hydrogen-induced cracking (HIC) tests to NACE TM0284 and sulphide stress cracking (SSC) tests to NACE TM0177, with ISO 15156 setting the framework for material selection. Inhibitors are screened in high-pressure autoclaves with a rotating cage or a rotating-cylinder electrode. An in-house laboratory needs the test vessels and fixtures, a gas panel, a scrubber and H2S detection.
The tests
HIC (NACE TM0284) – unstressed coupons are exposed to H2S-saturated solution, then sectioned and examined for cracks.
SSC (NACE TM0177) – stressed specimens in tensile, bent-beam, C-ring or double-cantilever-beam form are exposed until failure or for a set time.
Rotating cage (ASTM G184) and rotating cylinder electrode (ASTM G185) – inhibitor performance under flow.
Disbonding (ASTM G146) – clad plate for high-pressure, high-temperature hydrogen service.
The equipment
HIC vessels with coupon racks and gas spargers
Proof rings or constant-load frames and specimen fixtures for SSC
An alloy autoclave with rotating cage or rotating-cylinder electrode
A gas panel for H2S, CO2 and nitrogen, with purge
A caustic scrubber, extraction and fixed H2S detection
H2S safety
H2S is lethal at low concentrations. The laboratory needs gas detection with alarms, extraction, a scrubber for exhaust gas, breathing apparatus and trained staff. Equipment design keeps H2S inside closed vessels and lines from cylinder to scrubber.
Planning the laboratory
Size it to the number of specimens per month, allow for test durations of up to 30 days for SSC, and plan specimen machining and metallography alongside.
Where Tech Inc. equipment fits
Tech Inc. builds sour-service corrosion test kits, sour-gas autoclaves, stirred high-pressure reactors and gas panels.
Related reading
Sources
ASTM G184, Standard Practice for Evaluating and Qualifying Oil Field and Refinery Corrosion Inhibitors Using Rotating Cage – ASTM International
ASTM G185, Standard Practice for Evaluating and Qualifying Oil Field and Refinery Corrosion Inhibitors Using the Rotating Cylinder Electrode – ASTM International
ASTM G146, Standard Practice for Evaluation of Disbonding of Bimetallic Stainless Alloy/Steel Plate for Use in High-Pressure, High-Temperature Refinery Hydrogen Service – ASTM International
This guide is general information. Test methods and acceptance criteria follow the purchase specification and the standards it cites.