Process Note: Gas Supply for Gas Chromatographs, from Cylinders to Generators

Writer: Tech Inc
Tech Inc
8 hours ago
2 min read

At a glance. A gas chromatograph (GC) needs a carrier gas to move the sample through the column and, for flame ionisation detectors (FID), hydrogen fuel and zero air to sustain the flame. Many methods also use a makeup gas. Impurities in these gases raise baseline noise, shorten column life and cause drift. Laboratories across the world, in refineries, petrochemical plants, environmental testing and research, are replacing cylinders with on-site generators, driven by helium shortages and the risks of handling cylinders.

The gases and their jobs

  • Carrier gas: helium, hydrogen or nitrogen. Hydrogen gives fast analysis and good efficiency at higher flow rates, and it is the main alternative to helium.

  • FID fuel: hydrogen.

  • FID oxidant: zero air, with hydrocarbons reduced to very low levels.

  • Makeup gas: usually nitrogen.

  • Purge and actuation gas for valves and autosamplers.

Generators

  1. PEM hydrogen generators split deionised water into hydrogen and oxygen and dry the hydrogen to high purity. They hold only a small volume of gas, which lowers the fire risk compared with cylinders.

  2. Zero air generators pass compressed air through a heated catalyst that oxidises hydrocarbons, then remove water and particles.

  3. Nitrogen generators separate nitrogen from compressed air with membranes or pressure-swing adsorption.

  4. Gas stations combine hydrogen and zero air in one unit for FID instruments.

Design points

  • Flow demand of every instrument, including split vent flows and instruments planned for later.

  • Purity specification for each detector and method.

  • Changing from helium to hydrogen carrier, which needs method translation and checks of the column and inlet.

  • Hydrogen safety: leak detection, automatic shut-off on a leak, ventilation and suitable pipework.

  • Pipework: clean, leak-tested stainless steel or copper tubing with point-of-use regulators and traps.

  • Deionised water supply and routine maintenance for hydrogen generators.

Common problems

  • Baseline noise and ghost peaks from contaminated gas or exhausted traps.

  • Leaks, which are a safety issue with hydrogen and waste money with any gas.

  • FID flame-outs from unstable fuel or air flows.

  • Water in the carrier gas after a dryer failure, which can damage some columns.

  • Interrupted runs when cylinder changes are missed.