At a glance. Most centrifugal compressors in gas service use dry gas seals. Two rings, one rotating and one stationary, are held apart by a gas film only a few microns thick. The seal gas that forms this film must be free of particles and liquids. If heavy hydrocarbons condense as the gas expands across the seal faces, or if dirt reaches the faces, the seal can fail within hours and stop the compressor. Operators across the world fit seal gas conditioning to prevent this, and the API standards for compressor seal systems describe the supply in detail.

How the process works

  1. Source. Seal gas is usually taken from the compressor discharge, or from an external supply when the compressor is at standstill or starting up.

  2. Liquid removal. A coalescer or knock-out removes free liquids and aerosols.

  3. Filtration. Duplex seal gas filters, with fine absolute ratings, remove particles. Duplex housings let one filter be changed while the other is in service.

  4. Heating. A heater raises the gas temperature well above its hydrocarbon and water dew points, so no liquid forms when the gas cools as it expands across the seal.

  5. Boosting. At low compressor discharge pressure, during start-up, settle-out or slow roll, a booster keeps positive seal gas flow.

  6. Control and monitoring. Flow or differential pressure control maintains the supply to each seal, and transmitters monitor filter differential pressure, primary vent flow and separation gas.

Design points

  • Gas composition, from which the dew points and the required superheat margin are calculated across all operating cases.

  • Flow demand for each seal, including transients.

  • Filter rating and capacity, with differential pressure alarms.

  • Heater sizing and control, with protection against overheating.

  • Booster need, based on settle-out pressure and start-up cases.

  • Separation gas, usually nitrogen, to keep bearing oil away from the seals.

Common problems

  • Condensation at the seal faces where superheat was not enough at one operating point.

  • Contamination from bypassed or ruptured filters.

  • Oil migration from bearings when separation gas fails.

  • No seal gas during start-up, when discharge pressure is too low and no booster is fitted.

Where Tech Inc. equipment fits

Tech Inc. builds seal gas conditioning skids and supplies seal gas filter elements, nitrogen generator skids for separation gas and seal oil and barrier fluid systems for pumps. Each skid is engineered to the compressor vendor's seal requirements and the client's gas data, built in-house and factory-tested.

Related reading

This note is general guidance. Seal gas systems follow the compressor and seal manufacturers' requirements and the applicable standards.