top of page

Chemical Injection Skid Specification: 12 Things to Put in Your Datasheet Before You Ask for Quotes

Writer: Tech Inc
Tech Inc
Nov 7
5 min read

Corrosion inhibitor, scale inhibitor, methanol, demulsifier, H2S scavenger, biocide: a chemical injection package is one of the cheapest forms of insurance on a production system, and one of the most common enquiries we receive. It is also one of the easiest to under-specify.

When three vendors quote against a one-line request such as "CI skid, two pumps, 1,000-litre tank", you get three different machines at three different prices and no fair way to compare them. The checklist below is what our engineers ask for before we draw a P&ID. Put these twelve items in your datasheet and the bids you receive will line up, and the skid that arrives on site will be the one you needed.

1. The chemical, its SDS and its compatibility

Name the product and attach the supplier's safety data sheet. We need the specific gravity, the viscosity at your lowest ambient temperature, the flash point and whether the chemical is water-based or solvent-based. Viscosity drives pump suction design and heat tracing; flash point drives the electrical classification; and the chemistry drives material choice. Some inhibitors attack elastomers that are perfectly happy in methanol, so ask the chemical supplier for a compatibility statement covering seals, diaphragms and hoses.

2. Dose rate, turndown and the number of injection points

Give the flow as a range (minimum, normal and maximum, in litres per hour or per day) for each injection point. Say whether the dose is fixed or must follow production rate. API 675 controlled-volume pumps are expected to hold steady-state accuracy within ±1% over a 10:1 turndown. If your range is wider than that, the answer is a variable-speed drive combined with stroke adjustment, or two pumps of different sizes. If one chemical feeds several points, read our guide to multipoint chemical injection before you fix the architecture.

3. The real injection pressure

State the maximum pressure at every injection point, not the normal operating pressure. If a quill sits upstream of a choke, the pump must be able to inject against shut-in wellhead pressure. Add tubing losses, check-valve cracking pressure and quill losses, and the pump's discharge design pressure follows. Under-stating this is the single most common reason a skid has to be modified after delivery.

4. Pump type and redundancy

Packed plunger or hydraulic diaphragm? Electric or gas-driven? We compare them in detail in diaphragm vs plunger metering pumps. For critical duties such as hydrate inhibition or corrosion protection of an export line, specify duty and standby pumps (2 × 100%) with automatic changeover. Say whether your company standard requires API 675 compliance, because it affects pump selection and test scope.

5. Storage tank and autonomy

Size the tank in days of autonomy rather than litres: how often can a truck or boat refill it? Fifteen to thirty days is common on remote sites. Specify the material (SS316L is our standard), level gauge and level transmitter, low-level alarm and low-low pump trip, breather or vent arrangement, filling connection with filter, and whether the chemical needs a nitrogen blanket to keep moisture or oxygen out.

Tech Inc. multipoint chemical injection skid with stainless steel tank and metering pumps

6. Calibration column and flow measurement

A calibration column (calibration pot) on the pump suction lets operators confirm actual pump output against the set point in a few minutes, using nothing but a stopwatch. If you need injection rates in your DCS or SCADA, add a flow meter per point. Oval-gear, Coriolis and thermal meters each suit different flow ranges and chemicals, so tell us the range and we will select one.

7. Discharge protection and tie-in

Every positive-displacement pump needs a pressure relief valve on its discharge, sized for full pump flow and returned to the tank. Add pulsation dampeners where pipe runs are long or where flow meters need a smooth signal, a back-pressure valve where the injection point pressure is low (so check valves seat and the pump stays accurate), a suction strainer, and check valves plus double block and bleed at the process tie-in.

8. Controls, power and hazardous area

Tell us what power is available, whether the skid needs a local control panel, motor starters or variable-speed drives, and how it talks to your control system (hard-wired signals, 4 to 20 mA set points, Modbus). Give the hazardous area classification (for example Zone 1 or Zone 2, gas group and temperature class) and the certification you require: ATEX, IECEx, or PESO approval for installations in India. If there is no power at all, consider a solar-powered chemical injection skid.

9. Materials and sour service

SS316L wetted parts and seamless SS316 tubing with compression fittings are our default. Chloride-rich or sour fluids may call for duplex, super duplex or Inconel 625. If H2S is present anywhere in the system the skid connects to, say so, and require materials to NACE MR0175 / ISO 15156.

10. Skid structure, layout and access

Specify a drip tray or bund (110% of the tank volume is a common requirement), lifting lugs and forklift pockets, a sunshade for desert sites, and the maximum footprint and weight if the skid is going offshore or into a crowded wellpad. Ask for maintenance access to every pump from one side if the skid will sit against a wall.

11. Site conditions

Give minimum and maximum ambient temperature (a 55 °C design is normal in the Gulf), humidity, dust and sand exposure, and whether the site is coastal or offshore. These decide coating system, enclosure ratings, motor derating and whether viscous chemicals need heat tracing in winter.

12. Testing, documents and spares

Ask for a hydrostatic test of the discharge system, a pump performance and calibration test, and a factory acceptance test (FAT) witnessed by you or a third-party inspector. Specify the document package: P&ID, GA drawing, data sheets, material certificates to EN 10204 3.1, test reports and an operating manual. List commissioning spares and two-year operating spares so they are priced in the same offer.

A one-page datasheet you can copy

Item

What to give your vendor

Chemical

Product name, SDS, SG, viscosity at minimum ambient, flash point

Flow

Minimum, normal and maximum rate for every injection point

Pressure

Maximum injection pressure for every point, including shut-in

Pumps

Type, duty/standby, API 675 required or not

Tank

Days of autonomy, material, level instruments, blanketing

Power and area

Available supply, hazardous area class, certification

Controls

Local panel, remote signals, communication protocol

Materials

Wetted parts, tubing, NACE requirement

Site

Ambient range, offshore or onshore, sunshade, footprint

Quality

FAT, third-party inspection, document list, spares

Get a P&ID and quotation

Tech Inc. designs chemical injection skids in Vaughan, Canada and builds them in Chennai, India, from single-pump packages to multipoint and multi-compartment skids. Send your completed datasheet to mail@techincresearch.com or call +91 739 749 8656 and we will return a P&ID, GA drawing and priced offer. See the full range on our chemical injection systems page and our oil and gas systems overview.

Comments


bottom of page