Capillary Flow Porometers Compared: Every Tech Inc. Model Side by Side

Writer: Tech Inc
Tech Inc
8 hours ago
3 min read
Capillary Flow Porometers Compared: Every Tech Inc. Model Side by Side

Bottom line: for most membrane and filter-media work, the Advanced Pore Pro or Advanced Permeability Porometer covers about 0.013 to 500 µm at up to about 35 bar. The Simple Porometer suits teaching and routine QC. The specialist models measure under compression, without a wetting liquid, across a web or on whole cartridges.


The tables list each model with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your sample.


General-purpose porometers

Model

Code

Pore diameter

Pressure

Measures

Best for

TECH SIMPLE PORO

about 0.05 to 300 µm

up to about 14 bar (203 psi)

bubble point, mean flow pore size, distribution

teaching, routine QC, entry-level research

TECH PROPOR

about 0.013 to 500 µm

up to about 35 bar (508 psi)

automatic test sequence and report

membranes, filters, separators, fabrics

TECH PERRO

about 0.013 to 500 µm

up to about 35 bar (508 psi)

bubble point, mean flow pore, distribution, gas permeability; ASTM F316 and E1294 methods

pore size plus permeability

TECH FILTRA

about 0.013 to 500 µm

–

bubble point, mean flow pore, distribution, gas and liquid permeability; ASTM F316

meltblown, spunbond, glass-fibre, membranes

TECH NORM

–

–

active pore size

UF and NF membranes

AL500

MF and UF range

–

bubble point, mean flow pore size, distribution, gas permeability

laboratory and QC areas

AL500 EFM

finer distribution than the AL500

–

bubble point, mean flow pore, through-pore distribution; ASTM F316

compact bench format

AL1000

broader than the AL500, to NF-range materials

–

bubble point, mean flow pore, distribution, gas permeability; ASTM F316

tight UF and NF membranes

AL1000 EFM

as the AL1000, with extended flow measurement

–

the above in one run, higher-resolution distribution

narrow-distribution membranes


Specialist porometers

Model

Code

What is different

Measures

Samples

TECH COMPRESS

programmable stress during the test; about 0.013 to 500 µm

bubble point, mean flow pore, distribution and permeability against stress

GDLs, separators, felts, gaskets

TECH CYCLE

programmable cycles and hold times; about 0.013 to 500 µm

pore size, bubble point and permeability against cycles

GDLs, separators, filter media

TECH FC

stack-like clamping stress; about 0.013 to 500 µm

pore size distribution, bubble point, in-plane and through-plane permeability

GDL, MPL, PTL, catalyst-coated media

TECH HAPTER

no wetting liquid: humidity-controlled capillary condensation

through-pore distribution of fine pores

hydrophilic membranes, delicate films, biomaterials

TECH CAKE-PORO

measures while a filter cake builds; about 0.05 to 500 µm

pore size and permeability during cake build-up

filter media with cakes, fouled membranes

TECH MULTIPORE

several test heads run together

bubble point, mean flow pore and permeability at each point; cross-web map

membranes, nonwovens, separators on the roll


Filter integrity and cartridge testers

Model

Code

Tests

Samples

Output

TECH INTEGRYZER

bubble point, diffusion (forward flow), pressure hold

cartridges, capsules, discs, modules

pass/fail with recorded values

TECH CARALYZER

bubble point, diffusion, gas and liquid flow, water intrusion

cartridges 2.5 to 40 inch

full report per cartridge

TECH FILTER-CART

bubble point, diffusion flow, gas and liquid flow

cartridges to 10, 20, 30 and 40 inch

automatic pass/fail and recorded results

TECH CUSTRO

your procedure; heating, compression or liquid permeability options

holders built for your sample

your report format


How to choose

  • Smallest pore first: the bubble-point pressure of your tightest pore sets the pressure range you need.

  • Sample form: flat sheets, hollow fibres, cartridges and roll goods each need their own holder or test head.

  • Service conditions: GDLs and separators work under compression, so measure them that way.

  • Wetting liquid: if a liquid would damage or swell the sample, consider the humid-air method.

  • Throughput: for QC on the roll, multipoint testing saves repeat runs.


Not ready to buy? Our porometry testing service measures your samples in our own laboratory. All models: porometer range.


Before you order

Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.


Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.