Boiler water, feedwater, condensate and cooling water are monitored for chemistry that protects the whole plant. The analysis is only as good as the sample. ASTM D3370 is the standard practice for sampling water from flowing process streams. The current edition is D3370-25.

What it covers

According to ASTM's published scope, D3370 covers equipment and methods for sampling water from flowing process streams, such as those at power stations, for chemical, physical, microbiological and radiological analysis. It sets out three practices:

  • Practice A: grab samples.

  • Practice B: composite samples.

  • Practice C: on-line sampling.

It stresses that the goal is a representative portion, which depends on sampling points, materials, system design, timing, frequency and sample integrity, and it notes that multiple-point sampling is often needed.

Our commentary: choosing the practice

  • Grab samples suit periodic checks and analyses that cannot be done on-line, but they show one moment.

  • Composite samples average over time, useful for corrosion products and mass balances.

  • On-line sampling feeds analysers continuously and catches upsets as they happen.

Most plants use all three, from the same well-designed sample points.

What makes a water sampling point reliable

  1. Location: where the water is well mixed, away from dead ends and chemical injection points.

  2. Cooling: hot samples are cooled to a stable temperature before they reach people or analysers.

  3. Materials: stainless steel lines that do not add or remove what is being measured.

  4. Flow: steady, continuous flow keeps lines conditioned.

  5. Safety: pressure reduction, relief and thermal shut-off ahead of the sample panel.