top of page

ASTM D1066 Explained: Sampling Steam for Purity Monitoring

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Sodium, silica, iron, copper and cation conductivity in steam are measured at very low levels, and a poor sample hides them. ASTM D1066 is the standard practice for sampling steam. The current edition is D1066-18(2025).

What it covers

ASTM's published scope covers sampling saturated and superheated steam from fossil-fired and nuclear boilers and from other processes above atmospheric pressure, and also lower and sub-atmospheric steam where representative flow can be established. Its aim is a sample that represents the process steam, so that dissolved chemicals, solid particles and water droplets are measured accurately. The results show whether steam is within limits that prevent corrosion, erosion and deposits in turbines and process heat exchangers.

Our commentary: why steam is hard to sample

  • Two phases. Saturated steam carries water droplets with much of the dissolved salts. A nozzle that favours vapour or droplets biases the result.

  • Velocity. In practice, steam sampling nozzles are designed so that steam enters at the velocity of the main flow, known as isokinetic sampling, so droplets and particles are drawn in proportion.

  • Deposition in the line. Long, slow sample lines lose iron and copper oxides on the walls and release them later. Keep lines short, with steady flow.

  • Cooling. The sample must be condensed and cooled to a stable temperature before conductivity, sodium and silica analysers, or the readings drift.

  • Continuous flow. Steam sample lines should run continuously; stop-start flow sheds deposits.

What a steam and water analysis system includes

  1. Sampling nozzles in the steam lines.

  2. Primary and secondary sample coolers.

  3. Pressure reduction and temperature protection.

  4. Cation columns ahead of cation conductivity measurement.

  5. Analysers and a grab sample sink.

Tech Inc. equipment

For water samples from boiler, feedwater and condensate lines, see ASTM D3370.

Send your line data, product and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments


bottom of page