top of page

ASTM D1265 Explained: Manual Sampling of LPG into Two-Valve Cylinders

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Every specification test on LPG starts with a sample in a small steel cylinder. ASTM D1265 is the standard practice for taking it by hand. The current edition is D1265-23a.

What it covers

ASTM's published scope describes equipment and manual procedures for representative samples of specification LPG (products to ASTM D1835 and GPA 2140) using flow-through cylinders with two valves. It covers all routine LP gas tests under D1835, and may also apply to other volatile single-phase NGL products such as NGL mix, natural gasoline and field butane, where open containers would lose light components. It excludes single-valve cylinders and larger containers such as barbecue and forklift cylinders, and products with significant undissolved gas, free water or separate phases. For disputes over sample integrity under D1835, ASTM D3700 (floating piston cylinder) is the referee procedure.

Our commentary: the outage tube

A cylinder filled completely with liquid LPG is dangerous: a small rise in temperature makes the liquid expand and the pressure climb sharply. That is why LPG sample cylinders use an outage tube on one valve, which lets the operator vent liquid down to a fixed level and leave vapour space. Fit a relief device or rupture disc as well.

Practical points

  1. Purge the cylinder with product before taking the sample, so it contains LPG, not air or the previous product.

  2. Sample liquid, not vapour, from a point where the product is single-phase.

  3. Vent to the outage level in a safe direction, away from people and ignition sources.

  4. Check for leaks at the valves before transport.

  5. Keep cylinders clean and in service history; contamination affects sulphur and residue tests.

When D1265 is not enough

If a dispute is likely, or the product may lose light ends during manual sampling, use a floating piston cylinder; see our commentary on ASTM D3700.

Tech Inc. equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments


bottom of page