Application Note: Conditioning Well Gas for Pneumatic Instruments

Writer: Tech Inc
Tech Inc
5 days ago
2 min read

At a glance. Remote wellsites and pipeline stations often have no instrument-air compressor, so controllers, positioners and actuators run on gas taken from the well or the line. Untreated, that gas carries liquids and solids and cools as its pressure is reduced, so regulators freeze, controllers stick and actuators corrode. A small conditioning skid heats, separates, filters and regulates the gas before it reaches the instruments.

What goes wrong with raw gas

  • Liquids – condensate and water carried from the separator collect in regulators and controllers.

  • Hydrates and ice – gas cools across each pressure-reduction step; below its dew point, liquids and hydrates form.

  • Solids – scale and black powder plug small orifices.

  • Corrosion – wet sour gas attacks instrument internals.

How the gas is conditioned

  1. A scrubber removes free liquids, with a drain to a closed system.

  2. A heater raises the gas temperature enough to offset the cooling across the regulators.

  3. Coalescing and particulate filters remove mist and fines.

  4. Two regulators reduce the pressure in stages, with relief on each stage.

  5. A small volume tank lets actuators stroke without the supply pressure dipping.

Quality target

Instrument air is commonly specified to ISA-7.0.01 for dew point, particles and oil. Instrument gas cannot always meet the same numbers, but the same targets, dry, clean and stable, guide the design.

Emissions

Pneumatic devices vent gas in normal operation. Low-bleed instruments, a vent-recovery line or a change to electric or solar-powered actuation reduce the gas released.

Where Tech Inc. equipment fits

Related reading

Sources

This note is general information. Each skid is sized to the gas composition, pressures and instruments on the site.