At a glance. In steam and water analysis systems (SWAS), cation conductivity, also called acid conductivity, is the measurement plants watch most closely for contamination. It needs a column of strong-acid cation resin in the hydrogen form ahead of the conductivity cell. The resin exhausts in service, and when it does the reading drifts low and hides the contamination it is meant to show.

What the column does

Boiler and feedwater are dosed with ammonia or amines, which raise conductivity without being harmful. The cation resin swaps those cations for hydrogen ions, so the cell sees only the anions, such as chloride and sulphate, that signal a leak or carry-over. ASTM D6504 sets out the practice for this on-line measurement.

Signs of trouble

  • The colour band of indicating resin has moved most of the way down the column.

  • Cation conductivity drifts down while specific conductivity is unchanged.

  • Readings respond slowly after a load change.

Upkeep that keeps the reading right

  • Change or regenerate the resin before the colour band reaches the outlet.

  • Keep sample flow steady; most cells and columns are designed for a fixed flow.

  • Keep coolers clean and the sample temperature constant, as steam sampling practice in ASTM D1066 describes.

  • Check sample filters and flow meters at each resin change.

  • Consider degassed cation conductivity where carbon dioxide masks the result.

Spares to keep

Cation columns and sealed resin packs, cooler coils and gaskets, sample filters and flow meters, and an annual kit per panel.

Where Tech Inc. equipment fits

Sources

This note is general information. Chemistry limits and instrumentation follow the plant's cycle-chemistry guidelines.