top of page

Solar-Powered Chemical Injection Skids: How to Size the Panels, Batteries and Pump for a Remote Wellpad

Writer: Tech Inc
Tech Inc
Nov 7
3 min read

Remote wells often have no grid power and no instrument air, and pneumatic pumps that vent natural gas are under growing pressure from methane-emission rules. A solar-powered chemical injection skid answers all three, but only if the energy budget is done honestly. An undersized system works perfectly in the sunny week it is commissioned and stops injecting in the first dust storm or monsoon. Here is the method we use, with a worked example.

Step 1: work out the daily energy demand

Start with the loads, in watts, and how many hours a day each one runs:

  • The DC metering pump, at the power it draws at your injection pressure and rate (not its nameplate maximum).

  • The controller, RTU or PLC.

  • Telemetry: GSM, radio or satellite modem.

  • Any heaters, lights or instruments.

Worked example: a 50 W DC pump running continuously, plus 10 W for the controller and telemetry, is 60 W around the clock. Daily demand is 60 W × 24 h = 1,440 Wh per day.

Step 2: size the solar array for the worst month

Find the peak sun hours for the site in its worst month, not the annual average. Then allow for real-world losses: high cell temperature, dust on the panels, wiring and charge-controller losses. A combined derating factor of about 0.7 is a sensible starting point.

Worked example: with 5 peak sun hours and a 0.7 derating, the array must be at least 1,440 ÷ (5 × 0.7) ≈ 411 W. Round up to the next practical panel combination, for example two 250 W panels (500 W), and more if the worst month is cloudier than 5 sun hours.

Tilt the panels at roughly the site latitude for year-round output, and make sure they can be reached for cleaning. In desert locations, regular cleaning is the cheapest performance upgrade available.

Step 3: size the battery for autonomy

Decide how many days the skid must keep injecting with no useful sun. Three to five days is typical, longer where monsoon cloud or dust storms persist. Then divide by the usable depth of discharge of the battery chemistry.

Worked example (24 V system, 3 days autonomy):

  • Lead-acid at 50% depth of discharge: 1,440 × 3 ÷ 0.5 = 8,640 Wh, which is 360 Ah at 24 V.

  • Lithium iron phosphate (LiFePO4) at 80% depth of discharge: 1,440 × 3 ÷ 0.8 = 5,400 Wh, which is 225 Ah at 24 V.

Battery life falls sharply at high temperature, so the battery enclosure should be shaded, insulated and ventilated. On Gulf and Indian desert sites this matters as much as the amp-hour rating.

Tech Inc. solar-powered wellhead control panel with PV array and sunshade

Step 4: choose an efficient pump and controller

Every watt saved at the pump saves panels and batteries. Brushless DC motor-driven pumps with good mechanical efficiency make a large difference over a year. Use an MPPT charge controller, a low-voltage disconnect that protects the battery, and a pump controller that can take a rate set point and, if required, follow a production signal.

Step 5: add telemetry

A remote skid that nobody visits for weeks should report tank level, pump status, injection rate and battery voltage. Low tank level and low battery alarms let you send the refill truck or a technician before injection stops, not after the corrosion coupon tells you.

The worked example at a glance

Item

Value

Continuous load (pump + controls)

60 W

Daily energy

1,440 Wh

Design sun hours / derating

5 h / 0.7

Minimum PV array

411 W (select 500 W)

Autonomy

3 days

Battery, lead-acid 50% DoD

360 Ah at 24 V

Battery, LiFePO4 80% DoD

225 Ah at 24 V

These figures illustrate the method. Your own sizing should use the pump's actual power at your duty point and solar data for your site.

Design details that keep a solar skid running

  • Panel structure designed for site wind load, with anti-theft fixings where needed.

  • Cables sized for low voltage drop at 12 or 24 V, where losses add up quickly.

  • Earthing and lightning protection for the array and structure.

  • Panels located outside the hazardous area or suitably certified, with Ex-rated equipment inside the zone.

  • A sunshade over the chemical tank and controls to reduce temperature and UV damage.

Get a sized proposal

Our solar-powered chemical injection skid is sized for each site's chemical, rate, pressure and solar data. The same approach powers our solar-powered wellhead control panel. Send your site location, chemical, injection rate and pressure to mail@techincresearch.com or call +91 739 749 8656 for an energy calculation, P&ID and quotation. See all our chemical injection systems.

Comments


bottom of page