Lubrication Stations Compared: Flow, Filtration, Pressure and Power


Bottom line: for a rotating machine, the lube oil console supplies clean, cooled oil at about 50 to 1,500 L/min, designed to API 614. For a plant lube store, choose the containerised lube shelter with up to 12 oil lines, or the lube room dispensing system for an existing room. Before start-up, the flushing skid cleans piping to ISO 4406 targets; in service, the filtration cart and the vacuum dehydrators keep oil clean and dry.
The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.
Lube oil systems, stations and process skids
Product | Models | Flow or capacity | Pressure or temperature | Filtration, treatment or accuracy | Build and power |
|---|---|---|---|---|---|
TI-LOC-50 to TI-LOC-1500 | about 50 to 1,500 L/min; oil typically ISO VG 32 to 100 | – | typically 10 µm; flushed at FAT to ISO 4406 cleanliness | main and standby pumps, motor- or shaft-driven; API 614 | |
TI-SOS-52, 53A, 53B, 53C and 54, by API 682 plan | – | – | – | SS316 wetted parts; pressure and level instruments; ASME VIII pressure parts | |
TI-OFS-200 to TI-OFS-4000 | about 200 to 4,000 L/min | oil up to about 70 °C (158 °F) | down to about 3 µm, beta ratio 1,000 or better; online particle counter to ISO 4406 | electric with variable-speed drive, diesel on request; heaters about 24 to 120 kW by model | |
TI-MFC-10 to TI-MFC-60 | about 10 to 60 L/min | – | down to 3 µm | 220 V 1-ph or 380 V 3-ph | |
TI-VDS60 | 60 L/min; circulating systems typically 20–45 m³ | vacuum dehydration at low temperature | water from typically 3,000–150,000 ppm down to the mill limit, typically 500 ppm | PLC with water-in-oil sensor; skid-mounted | |
– | sized to the hydraulic system | vacuum dehydration at low temperature | removes free, emulsified and dissolved water; 3 micron filtration | PLC with water-in-oil sensor and filter alarm | |
TI-EHP-10, 20 and 40 | about 10 to 40 L/min | – | ion-exchange resin or activated alumina | materials compatible with phosphate ester; hazardous-area versions | |
TI-CLU-20 (up to 6 lines), TI-CLU-40 (up to 12 lines) | 2–3 GPM per line; oils 50–500 cSt | 5–12 bar (73–174 psi) | – | 380 V 3-ph or 220 V 1-ph, 50/60 Hz; IP65 panel for 50 °C (122 °F) ambient | |
TI-LRD-4 to TI-LRD-12 lines | oval-gear meters for 50–500 cSt | 5–12 bar (73–174 psi) | – | gear, vane or pneumatic piston pumps; site voltage, 50/60 Hz | |
TI-BOS-2, 4 and 6 tanks; 110 to 900 L each | oils up to ISO VG 680 | – | 4 to 25 micron; water-removal elements on request | electric (230 V single-phase) or air-operated pumps; spill base for 110% of the largest tank | |
TI-LTS-2, 4, 8 and T; about 2,000 to 8,000 L | four to seven compartments | – | delivery filters | air-operated oil and grease pumps; compressor and receiver | |
TI-ALS-P50, P200, D500 and M | about 50 to 500 points | – | – | electric or pneumatic pumps; grease up to NLGI 2, or oil; progressive or dual-line | |
TI-LBS-B5, B20, I30, I100 and P | about 5 or 20 t batches; about 30 or 100 m³/h in-line; pilot about 100 to 500 L | heated lines and vessels | about 0.1 to 0.5% of each component | up to about 12 components; Ex-rated components where required | |
TI-LFF-60, 150 and 300 | about 60 to 300 L/min | heating on request | bag or cartridge filters about 1 to 25 µm; fill typically within about 0.1% of weight | Ex-rated build on request | |
TI-LAD-3, 6, 10 and PM | about 1 to 500 L/h per additive; premix vessel about 1 to 5 m³ | heating to about 80 °C (176 °F) | dosing accuracy about 0.5% with mass-flow measurement | Ex-rated build where required | |
TI-GCK-100 to TI-GCK-10000 | batches about 100 kg to 10 t | contactor to about 10 barg (145 psig) and about 230 °C (446 °F) | mill, homogeniser or deaerator finishing | thermal-oil jackets; ASME VIII Div. 1 contactor |
Transfer, grease and housekeeping products
Product | Sizes | Key data | Materials | Seals |
|---|---|---|---|---|
1.5, 2, 3, 5 and 10 L | spout lids to about ISO VG 220; utility and pump lids to ISO VG 680; up to 11 colours | HDPE body; ABS / polypropylene lids | nitrile or Viton | |
hose 1.5 m or 3 m; fits 5 L and 10 L containers | about 80 ml per stroke; up to ISO VG 460 (standard) or ISO VG 680 (premium) | clear PVC hose | nitrile or Viton | |
50 to 205 L drums, 2-inch bung | about 0.3 to 0.5 L per turn or stroke | aluminium or steel | nitrile or Viton | |
hoses 300 and 450 mm, 1/8 in NPT; pails 18 to 25 kg | up to about 690 bar (10,000 psi), depending on gun type | steel or clear barrels, up to 10 colours | – | |
three sizes; 80-piece SAE or metric kits | up to 6 colours | – | – | |
pockets, frames, drum rings, washers, tabs and magnets | up to 11 colours, plus symbols for colour-blind users | polyester, laminated card, water-resistant paper | – | |
NPT, BSPP and metric threads | about -40 to 95 °C (−40 to 203 °F) | polyamide or glass-filled bodies; aluminium or steel adapters | nitrile or Viton | |
1 in or 3/4 in NPT, with adapters | particle filtration about 3 micron; silica gel changes colour when spent | – | – | |
sump sized to the largest container (205 L drum or more) | removable gratings | polyethylene, steel or stainless | – |
How to choose
Start from the oil grade and viscosity: pumps, meters and filters must suit the heaviest oil you handle.
Set the cleanliness target: the ISO 4406 code your machines need sets the filter rating.
Keep oils apart: one line, container and colour per lubricant avoids cross-contamination.
Water does as much harm as dirt: breathers keep it out and a dehydrator removes it when it gets in.
Check power supply and area classification for every skid that goes into a plant area.
All models: lubrication stations range.
Before you order
Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.
Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.