Liquid Metering Skids for Custody Transfer: Coriolis, Ultrasonic, Turbine or PD Meter?

A custody transfer metering skid turns flow into money, so every component on it is there to make the measured quantity defensible. The meter is the part buyers focus on, but the choice only makes sense alongside the prover, the flow computer and the way the skid is laid out. A good meter on a poorly designed skid still produces numbers nobody trusts. This guide is for metering engineers and buyers specifying a liquid metering skid for crude, condensate or refined products.
What sits on a liquid metering skid
Inlet header with strainers or filters, and an air eliminator where the supply can carry vapour, such as truck unloading.
Meter runs, each with isolation valves, the meter, flow conditioning where the meter needs it, and pressure and temperature transmitters.
Density measurement where mass, or volume at reference conditions, is calculated from density.
An automatic sampler for water and sediment and for laboratory quality tests.
A prover or a prover connection: pipe prover, small-volume prover or master meter.
A flow or back-pressure control valve, keeping pressure above the liquid's vapour pressure.
Flow computer and supervisory system for calculations, records and reports.
The four main meter technologies
API MPMS Chapter 5 covers metering, with separate sections for each technology: Chapter 5.2 for displacement (PD) meters, 5.3 for turbine meters, 5.6 for Coriolis meters and 5.8 for transit-time ultrasonic meters. The comparison below gives typical behaviour; confirm limits with the meter maker for your product and conditions.
Meter | Measures | Best suited to | Watch for |
PD (Ch. 5.2) | Volume, by trapping fixed volumes | Viscous crude and products; good at low flow | Moving parts wear; pressure drop; sensitive to dirt |
Turbine (Ch. 5.3) | Volume, from rotor speed | Clean, low-viscosity products such as refined fuels | Sensitive to viscosity changes; needs flow conditioning |
Coriolis (Ch. 5.6) | Mass directly, plus density | Wide viscosity range; mass-based transfers; small and medium lines | Higher pressure drop; cost rises steeply with size |
Ultrasonic (Ch. 5.8) | Volume, from transit time | Large lines and high flows; no added pressure drop | Needs flow conditioning; proving needs care, often larger prover volumes or more runs |
Choosing between them
Start with the product and the line size. Viscous crude often points to PD or Coriolis meters; clean, light refined products suit turbines; very large crude lines are where ultrasonic meters show their strengths. Then look at the operating envelope: how widely viscosity and temperature vary, the flow turndown and the available pressure drop. Where a skid handles several products, the meter must cope with all of them, or each product needs its own proven meter factor. Finally, consider how the meter will be proved. A meter that cannot be proved repeatably on site is a meter whose factor nobody trusts.
Mass or volume
Most crude and refined product contracts trade in volume at reference conditions, while some LPG and NGL contracts trade in mass. Coriolis meters measure mass directly and need density to report volume; volumetric meters need density to report mass. Either way, the flow computer must apply exactly the correction method the contract names, and the density measurement becomes part of the custody chain.
Proving
API MPMS Chapter 4 covers proving systems. A prover of known volume, or a master meter, is run in series with the duty meter, and the ratio between the prover's volume and the meter's indicated volume gives the meter factor. Proving is repeated until a set number of consecutive runs agree within the repeatability the standard or contract requires. Decide early whether the skid carries a permanent prover, shares one with other skids or uses a mobile prover, because this sets the valve arrangement, the space and the cost.
Meter factors change with flow rate, viscosity, temperature and wear, so prove at the conditions the meter actually runs at, and re-prove when the product or conditions change. A control chart of meter factors over time is one of the simplest ways to spot a meter that is starting to wear.

Flow computer and calculations
The flow computer turns meter pulses or mass signals into quantities at reference conditions and keeps the audit trail. API MPMS Chapter 21.2 covers electronic liquid volume measurement using displacement and turbine meters, including what the flow computer must record. Chapter 11.1 provides the temperature and pressure volume correction factors used to convert to standard conditions, and Chapter 12 sets out how petroleum quantities are calculated and rounded. Where legal metrology applies, OIML R117-1 sets requirements for dynamic measuring systems for liquids other than water. Your contract will name which documents and editions govern; the flow computer configuration must follow them exactly.
Skid design points
Duty and standby runs, or N+1 runs, so one meter can be proved or serviced without stopping the transfer.
Double block and bleed valves wherever leakage would bypass the measurement, such as prover diverter and run isolation valves, with the bleed proving the seal.
Pressure drop budgeted across strainers, meters, conditioning and valves at maximum flow.
Back-pressure held above the vapour pressure of the product at the meter, so no vapour forms in the measurement.
Thermal relief valves on every section that can be blocked in full of liquid.
Sampling located where the stream is mixed, with flow-proportional pacing from the meter.
Straight lengths and flow conditioning as the meter maker and standard require.
Strainers sized for realistic dirt loads, with differential pressure indication so a blocking strainer is seen.
Access for removing meters, inspecting strainers and connecting a mobile prover.
What to specify
Product, density and viscosity range, temperature and pressure.
Flow range, batch sizes and required uncertainty.
Governing standards, contract terms and any legal metrology approval needed.
Number of runs, meter type preference and proving method.
Sampling and quality measurement requirements.
Flow computer, supervisory system and SCADA interface.
Hazardous area classification, utilities and site layout.
Get a metering skid offer built around your product
We design liquid metering skids and truck and tanker loading and unloading skids in Vaughan, Canada and build them in Chennai, India, with in-line automatic sampling and flow computers integrated. Each skid is factory acceptance tested, witnessed by the client or a third-party inspector, with EN 10204 3.1 material certificates. For the sampling side of custody transfer, read automatic crude oil sampling for custody transfer. Browse our metering and loading skids and the full oil and gas systems range. Send your product data, flow range and governing standards to mail@techincresearch.com or call +91 739 749 8656 and we will return a P&ID, GA drawing and priced offer.