top of page

Hypochlorite Ageing Tests: Proving a PVDF Replacement Survives Years of Cleaning

Writer: Tech Inc
Tech Inc
2 days ago
2 min read

Hollow fibre and flat-sheet UF membranes are cleaned with sodium hypochlorite throughout their lives. PVDF became the standard largely because it tolerates that. Any PFAS-free replacement must show the same tolerance, and the way to show it is an accelerated ageing test.

The principle

Membrane samples are soaked in hypochlorite at a higher concentration than in plant cleaning, so that weeks in the laboratory represent years of cleaning cycles. Samples are taken out at intervals and tested. The exposure is usually expressed as concentration multiplied by time.

What published studies show

  • PVDF hollow fibres: a 2022 study soaked three commercial PVDF hollow fibres in 2,000 ppm hypochlorite at pH 10 (and pH 8 for one) for up to 500 hours. The hydrophilic additive degraded and surface pores opened, but mechanical strength was essentially unchanged. That is the bar a replacement has to meet.

  • Polysulfone: a study from Toulouse immersed polysulfone fibres in 100 ppm hypochlorite for up to 16 days and converted the exposure to equivalent years of operation. Permeability rose and retention fell, but mechanical strength dropped sharply. pH 8 to 10 and higher temperatures were the most damaging.

The second result carries the key lesson: permeability alone is a poor indicator of ageing. A membrane can look better in a flux test while it is becoming brittle.

A practical test plan

  1. Prepare enough samples from one batch for every test point.

  2. Soak at fixed concentration, pH and temperature, protected from light, and keep the hypochlorite topped up.

  3. At each interval, measure: - clean water permeability on a flux QC tester; - rejection or MWCO; - tensile strength and elongation on a tensile tester; - bubble point and pore size on a porometer; - contact angle.

  4. Run PVDF alongside as the reference.

  5. Repeat at more than one pH, because pH changes which reactions dominate.

Reading the results

Compare each property against PVDF at the same exposure. A candidate that matches PVDF on strength and keeps its pore structure is worth taking to pilot; one that gains flux while losing strength is not ready. See also PVDF and the PFAS restriction.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Equipment specifications are typical and may change. Test results depend on the membranes, waters and conditions tested, how the equipment is used and operation in line with the operation manual.