top of page

Contract Laboratory Testing for Membranes, Filters and Porous Materials

Writer: Tech Inc
Tech Inc
23 hours ago
3 min read

At a glance. Tech Inc. now offers contract testing on the instruments we design and build. You send samples, we agree the method and conditions, run the tests and return a report with raw data. Results stay confidential, and we sign an NDA on request. Start at Laboratory Testing Services.

Who uses contract testing

  • Manufacturers checking a new membrane, filter medium, separator or nonwoven before scale-up.

  • QC teams that need an independent second result or extra capacity at month end.

  • Researchers who need one data set for a paper or thesis without buying an instrument.

  • Instrument buyers who want to see how a porometer, permeameter or test rig performs on their own materials first.

The tests we run

Test

What you get

Methods

Service page

Capillary flow porometry

Bubble point, mean flow pore, pore size distribution

ASTM F316, ASTM E1294

Porosity and porosimetry

Porosity, pore volume, pore size by intrusion or extrusion

ISO 15901-1, liquid extrusion, pycnometry

Air and gas permeability

Gurley seconds, Frazier air flow, gas permeance

ISO 5636-5, TAPPI T 460, ASTM D737

BET surface area and density

m²/g, BJH pore size, skeletal density

ISO 9277, helium pycnometry

Membrane flux and rejection

Pure water flux, permeability, salt or solute rejection

Crossflow at your conditions

MWCO

Retention curve and molecular weight cut-off

Dextran or PEG markers, ASTM E1343 practice

Contact angle

Static, advancing and receding angles, surface energy

ASTM D7334, ISO 19403 practice

Tensile strength

Break strength, elongation, modulus of films and fibres

ASTM D882 practice

Filter integrity

Bubble point, diffusion, pressure hold on cartridges and discs

Maker's procedure, ASTM F316

Core analysis

Helium porosity, gas and liquid permeability of plugs

API RP 40 practice

WVTR and OTR

Water vapour and oxygen transmission rates

ASTM F1249, ASTM E96, ASTM D3985

Burst and pressure

Burst pressure, proof, pressure hold, leak rate

Your specification, ISO 1402 for hoses

How it works

  1. Tell us what you need. Email mail@techincresearch.com or call +1 (289) 622-1032 with the material, the tests, the number of samples and any standard you must follow.

  2. Quotation and sample form. We confirm the method, conditions, specimen size and price.

  3. Send samples. Label each one; three specimens per material give a useful spread for most tests.

  4. Testing. Run on calibrated Tech Inc. instruments under the agreed conditions.

  5. Report. Method, conditions, results, charts and raw data files. Questions on the data are answered by the engineer who ran the test.

Getting useful results

  • Say how the material is used. A battery separator, a sterile filter and a geotextile need different wetting liquids, pressures and pore ranges.

  • Send enough material. Spare specimens allow a repeat if one is damaged.

  • Mark orientation. Machine and cross direction matter for tensile and air permeability.

  • Keep samples clean and dry, unless the test calls for wet membranes.

Frequently asked questions

Can you test to our own procedure? Yes. Send it with the enquiry and we confirm what our instruments can follow.

Do you test competitors' products? Yes, for benchmarking. Results are reported only to you.

Can testing lead to an instrument? Often. Many buyers test first, then order the same porometer, permeameter or membrane test system for their own laboratory.

Comments