top of page

Process Note: Compressed Air Treatment and Drying to ISO 8573-1

Writer: Tech Inc
Tech Inc
8 hours ago
2 min read

At a glance. Compressed air leaves the compressor hot and saturated with water, and it carries particles from the intake and oil from the compressor. If these reach instruments, valves, process users or products they cause corrosion, sticking valves, frozen lines and contamination. Treatment removes them to a purity that suits each use. Plants across the world specify that purity with ISO 8573-1, which sets classes for solid particles, water and total oil.

The treatment train

  1. Intake filter on the compressor.

  2. Aftercooler, which cools the air and condenses most of the water.

  3. Moisture separator and drain, with zero-loss drains where possible.

  4. Receiver, which buffers demand and lets more water drop out.

  5. Coalescing prefilters, which remove oil aerosols and fine droplets that would damage the dryer.

  6. Dryer: refrigerated (pressure dew point around +3 °C), desiccant (−40 °C or −70 °C) or membrane, which suits point-of-use duties and remote sites.

  7. Particulate after-filter, which catches desiccant dust.

  8. Activated carbon where oil vapour must be removed, for example for breathing air or food contact.

Reading an ISO 8573-1 class

A class is written as three numbers for particles, water and oil, for example Class 1.2.1, and a lower number is cleaner. The water class is set by pressure dew point: Class 2 is −40 °C and Class 4 is +3 °C. Instrument air is often specified with a dew point at least 10 °C below the lowest ambient temperature the lines see, following ISA-7.0.01.

Design points

  • The purity each user really needs, as treating all the air to the highest class wastes energy.

  • Ambient temperature and humidity, which set the water load.

  • Pressure drop across filters and dryers, which costs compressor energy.

  • Purge air used by desiccant and membrane dryers.

  • Oil-free or oil-injected compressors, and the oil carryover each produces.

  • Condensate handling, as condensate from oil-injected compressors needs oil–water separation before disposal.

Common problems

  • Water in the lines after a dryer bypass or a failed drain.

  • Oil carryover that saturates desiccant or downstream filters.

  • High pressure drop from filters not changed on time.

  • Frozen instrument lines outdoors when the dew point is too high for winter.

  • Energy waste from timed drains and excessive purge.

Where Tech Inc. equipment fits

Related reading

This note is general guidance. Air purity requirements follow the equipment makers' requirements and the applicable standards for each use.

Comments