ASTM G93 Explained: Cleanliness for Oxygen Service Equipment

Oxygen makes things burn that would never burn in air, and hydrocarbon contamination makes it worse. Equipment for oxygen and oxygen-enriched gases must be clean, and stay clean, before it sees oxygen. ASTM G93 is the standard guide to cleanliness levels and cleaning methods for that equipment. The current edition is G93/G93M-25.
What it covers
ASTM's published scope covers selecting cleanliness levels, cleaning methods and related practices for materials, components and equipment used in oxygen-enriched environments, together with inspecting cleaned items and keeping them clean until they enter service. It explains why: oil and grease films ignite more readily than bulk materials and can feed a kindling chain, and metal debris can also ignite. The guide does not set one acceptable cleanliness level for every application. It gives codes for designating cleanliness levels, expresses contaminant mass per unit area, and describes qualitative and quantitative inspection methods.
Our commentary: what this means for a gas panel
Design first. Cleaning cannot fix a design with dead ends that trap particles, or materials that are not oxygen-compatible.
Clean every wetted part, then assemble in clean conditions; a clean component handled with oily gloves is no longer clean.
Specify the cleanliness level in the order, since G93 leaves the level to the user.
Inspect and record: visual and ultraviolet checks for hydrocarbons, and quantitative tests where the level calls for them.
Seal and bag cleaned items until installation.
Open valves slowly in service; rapid pressurisation heats gas by compression and is a classic ignition source.
Tech Inc. equipment
Oxygen-Service Gas Panel and Manifold: every part chosen for oxygen compatibility and cleaned to ASTM G93 practice.
Automatic Gas Changeover Manifold, with oxygen-service versions cleaned to ASTM G93.
See the high-pressure gas systems range.
Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.
This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.
Sources
ASTM International, ASTM G93/G93M-25 Standard Guide for Cleanliness Levels and Cleaning Methods for Materials and Equipment Used in Oxygen-Enriched Environments, standard summary page.