ASTM D664, Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration (D664-24) and ASTM D2896, Standard Test Method for Base Number of Petroleum Products by Potentiometric Perchloric Acid Titration (D2896-26) report, in milligrams of potassium hydroxide per gram of sample, how acidic or how basic an oil is.

What they cover

ASTM's scope for D664 covers petroleum products, lubricants, biodiesel and biodiesel blends, with Test Method A for oils soluble in toluene and propan-2-ol and Method B developed for biodiesel; the precision covers 0.5 to 90 mg KOH/g. D2896's scope covers the titration of basic constituents with perchloric acid in glacial acetic acid, with Procedures A and B differing in solvent volume and sample mass, and an alternative solvent system that avoids chlorobenzene. The basic constituents include organic and inorganic bases, amino compounds and soaps: in a crankcase oil, essentially the over-based detergent package.

Our commentary

  • TAN for industrial oils, TBN for engine oils. Turbine, hydraulic and compressor oils have no reserve alkalinity; their acid number climbs from a fraction of a unit as oxidation products form, and a doubling over new-oil is a common change-out trigger. Engine oils start with a TBN of several units to neutralise combustion acids and are changed when it has fallen to roughly half.

  • Two methods, two numbers. D2896 (perchloric acid) reads higher than the hydrochloric acid method (D4739) on the same used oil because it titrates weaker bases; a specification must name the method.

  • Blending control. On a blending skid the additive package sets the TBN; a titration on the finished batch confirms the dosing before filling.

  • Watch the trend with water and viscosity. A rising TAN with rising viscosity is oxidation; a rising TAN with falling flash point is fuel or process contamination.

Our equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments