top of page

ASTM D6556 Explained: Total and External Surface Area by Nitrogen Adsorption

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Carbon black reinforces tyres and rubber goods, and its surface area decides how it interacts with the rubber. ASTM D6556 measures that surface area by nitrogen adsorption. The current edition is D6556-21.

What it covers

ASTM's published scope covers two values for carbon black:

  • Total surface area (NSA) by the BET theory of multilayer nitrogen adsorption, multipoint, which includes micropores under 2 nm;

  • External surface area (STSA) by the statistical thickness method, which represents the area accessible to rubber.

Because the separate CTAB method (D3765) has been withdrawn, the scope notes that a CTAB value can be estimated from STSA.

Our commentary: why two numbers

Micropores inside carbon black particles add to BET area but are too small for rubber molecules to enter. STSA leaves them out, so it tracks reinforcement better; the gap between NSA and STSA indicates microporosity.

Good practice for nitrogen adsorption

  1. Degas properly. Moisture and adsorbed vapours hide surface; degas at the stated temperature until weight is stable.

  2. Measure saturation pressure (P0) during the run, not just once a day.

  3. Use the right relative-pressure range for the BET fit, and check the fit's constant is positive.

  4. Enough surface in the tube. Too little sample gives noisy results.

  5. Reference materials with certified area confirm the instrument.

Beyond carbon black

The same BET method, under ISO 9277, is used for catalysts, battery materials, pharmaceuticals and membrane materials.

Tech Inc. equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments