The heating value and relative density on a natural gas invoice come from its composition, measured by gas chromatography. ASTM D1945 is the standard test method for that analysis. The current edition is D1945-25.

What it covers

ASTM's published scope covers the composition of natural gas and similar mixtures: hydrocarbons, helium, hydrogen, oxygen, nitrogen, carbon dioxide and hydrogen sulphide. Most components can be detected down to about 0.01 mole %, hydrogen sulphide to about 0.3 mole %, and upper ranges run from about 1 to 100 mole % depending on the component. Results are used to calculate properties such as heating value and relative density, or to monitor composition.

Our commentary: the analysis is only as good as the sample

D1945 assumes the GC receives gas that represents the pipeline. In practice, most errors come before the chromatograph:

  • Condensation. Cooling a rich gas below its hydrocarbon dew point drops heavy components out as liquid, so the sample reads lean and the heating value low. Heat the sample line and regulator.

  • Pressure letdown cooling. Reducing pressure chills gas (the Joule–Thomson effect); heat at the regulator prevents condensation.

  • Lag time. Long, slow sample lines make the GC report old gas; a fast loop fixes this.

  • Spot vs composite. A spot sample shows one moment; a flow-proportional composite sample represents a whole delivery period.

  • Adsorption. Hydrogen sulphide and heavy components stick to some surfaces; use suitable materials.

Tech Inc. equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.