Stainless steel resists corrosion because of a thin chromium-rich oxide film. Fabrication damages it: weld heat tint, embedded iron from tools, oil and shop dirt all start corrosion. ASTM A380 is the standard practice for cleaning, descaling, pickling and passivating stainless steel parts, equipment and systems. The current edition is A380/A380M-25.

What it covers

ASTM's published scope gives recommendations and precautions for cleaning, descaling and passivating stainless steel parts, assemblies, equipment and installed systems, to remove contaminants that could impair corrosion resistance or contaminate a process fluid. It includes qualitative passivation tests with acceptance criteria, which are also found in ASTM A967/A967M. The procedures are for reference rather than mandatory; the choice of procedure and any extra requirements are agreed between supplier and purchaser. It does not cover in-service decontamination or mill descaling, and it leaves safety and environmental practices to the user.

Our commentary: the sequence on site

  1. Degrease to remove oil and shop dirt.

  2. Rinse.

  3. Pickle to remove weld heat tint and scale, typically with acid blends suited to the alloy.

  4. Rinse until neutral.

  5. Passivate, typically with nitric or citric acid, to rebuild the passive film.

  6. Final rinse with clean water and test.

Common mistakes

  • Skipping degreasing, so acids cannot reach the metal.

  • Wrong temperature or contact time, giving incomplete pickling or attack.

  • Chloride-containing rinse water, which starts pitting on fresh surfaces.

  • No records. Temperatures, concentrations, times and test results should be logged for the dossier.

  • Waste handling. Spent acids need neutralisation and proper disposal.

Tech Inc. equipment

  • Chemical Cleaning, Pickling and Passivation Skid: circulates heated cleaning chemicals through piping, vessels and heat exchangers, with pH, conductivity, temperature and iron sampling; cleaning sequences to the client procedure, for example ASTM A380 and A967.

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.