Process Note: Oxygenation in Recirculating and Seawater Fish Farms

At a glance. Recirculating aquaculture systems (RAS) and intensive hatcheries stock fish at high density. Aeration alone cannot supply enough oxygen, so farms dissolve pure oxygen into the water. Efficient contactors, good control and corrosion-resistant materials keep oxygen high at low cost.
Dissolving the oxygen
Oxygen cones (downflow bubble contactors) take a side stream of water under pressure. Water enters at the narrow top and slows as the cone widens, so bubbles stay in contact until they dissolve. Transfer efficiency is high.
Low-head oxygenators treat large flows at low lift, suiting systems where pumping energy matters.
Diffusers in tanks are simple but less efficient.
Supplying the oxygen
PSA oxygen generators make oxygen on site from air.
Liquid oxygen from a tank and vaporiser suits larger farms or backup.
A gas panel with regulators, flow meters and solenoid valves delivers oxygen to each contactor.
Controlling dissolved oxygen
Dissolved-oxygen probes in each tank or in the return water feed a controller that opens or closes the oxygen supply. Low-oxygen alarms and a backup supply protect the stock if a generator or pump fails.
Materials
Seawater and brackish water corrode ordinary stainless steel, especially in warm water under pressure. Super duplex stainless steel resists pitting and crevice corrosion in these conditions, and it is strong enough for pressurised cones. Fresh-water systems can use 316L.
Common problems
Oxygen wasted through undissolved bubbles leaving the contactor.
Probes drifting because they are not cleaned and calibrated.
Gas supersaturation when too much oxygen is added at once.
Where Tech Inc. equipment fits
Tech Inc. builds the super-duplex aquaculture oxygenation skid and supplies dissolved oxygen meters and gas panels. Our super-duplex seawater coolers use the same welding procedures.
Related reading
Sources
Chemical features of water: dissolved oxygen (aquaculture training manual) – Food and Agriculture Organization of the United Nations
ASTM A923, Detecting Detrimental Intermetallic Phase in Duplex Austenitic/Ferritic Stainless Steels – ASTM International
This note is general information. Oxygen demand depends on species, stocking density, temperature and feeding.