top of page

The Tech Inc. High-Pressure CO2/CH4 Membrane Test Skid tests membranes and modules for removing CO2 from natural gas and biogas at the pressures they run at. CO2, methane and nitrogen are blended and boosted to the test pressure; heated housings hold flat-sheet cells or hollow-fibre modules; back-pressure regulators set the feed pressure and stage cut; and a gas chromatograph analyses feed, residue and permeate. Pressure steps show how CO2 permeance and CO2/CH4 selectivity change as CO2 partial pressure rises, the plasticisation test every glassy membrane has to pass.

At a glance: CO2/CH4 mixed gas at pressure · heated housings for cells or modules · plasticisation steps · H2S option · GC analysis

Download the datasheet (PDF)

 

Main components

  • Gas supply for CO2, CH4 and N2, with H2S option
  • Mass flow controllers and gas booster
  • Heated high-pressure housings for flat-sheet cells or hollow-fibre modules
  • Back-pressure regulators on residue and permeate
  • Gas chromatograph with stream selection
  • Guarded enclosure with gas detection and extraction
  • Control cabinet with PLC, touch-screen HMI and reports

 

Applications: Membrane makers developing natural gas sweetening and biogas upgrading membranes; gas processors qualifying modules; universities testing plasticisation-resistant polymers, carbon molecular sieve and mixed-matrix membranes.

 

Send your membranes, gases and test conditions to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.

High-Pressure CO2/CH4 Membrane Test Skid

bottom of page