Sizing Two- and Three-Phase Production Separators

At a glance. A production separator splits a well stream into gas and liquid, or into gas, oil and water. Its size is set by two checks: the gas must flow slowly enough that droplets fall out, and the liquid must stay long enough for gas to escape and, in a three-phase unit, for oil and water to part. Whichever check needs the bigger vessel decides the size.
Gas capacity
The gas velocity in the vessel must stay below the speed at which droplets are carried out. Designers use the Souders–Brown relation, in which the allowable velocity depends on the gas and liquid densities and a K factor set by the vessel orientation and the mist extractor. A mesh pad or vane pack lets the vessel run faster than open gravity separation; an inlet device that breaks the incoming momentum keeps the gas section calm.
Liquid retention
Two-phase. Liquid retention times of roughly one to three minutes are common, longer for foaming or heavy crude.
Three-phase. Oil and water need longer, often several minutes to ten minutes or more, depending on the crude gravity, temperature and how readily the emulsion breaks. API 12J gives guidance values.
Surge. Extra volume is added for slugs from flowlines and for the time between level alarms and trips.
Orientation and internals
Horizontal vessels suit high liquid loads and three-phase separation, with a long interface area and a weir or bucket to keep oil and water apart.
Vertical vessels suit gas-dominated streams and small plots, and handle sand more easily.
Internals: inlet diverters or cyclones, perforated calming baffles, weirs, vortex breakers, mist extractors and, where needed, sand jets and drains.
Other design points
Design pressure and temperature, relief sizing, sour service materials to NACE MR0175 / ISO 15156, corrosion allowance, level and pressure control valves, metering on each outlet, and access for inspection.
Where Tech Inc. equipment fits
Tech Inc. builds two- and three-phase production separators, test separator packages, wellhead desander skids and early production facilities.
Related reading
Sources
This guide is general information. Each separator is sized from the process datasheet and built to the project specification and code.