Hydrotreating Pilot Plants: How a Hydroprocessing Test Unit Works and How to Specify One

At a glance. Hydrotreating passes a refinery stream with hydrogen over a sulphided CoMo or NiMo catalyst at roughly 300 to 400 °C and elevated hydrogen pressure to remove sulphur (HDS), nitrogen (HDN) and metals and to saturate olefins and aromatics. Because catalyst choice, pressure, temperature and space velocity decide product quality and catalyst life, refiners and catalyst makers test them first in a hydroprocessing pilot plant: a small trickle-bed reactor with hydrogen and liquid feed, high- and low-pressure separators, product sampling and analysis, and hydrogen and H₂S safety systems.
What is hydrotreating?
Hydrotreating (also called hydroprocessing or hydrodesulphurisation when sulphur is the target) is the refinery process that cleans naphtha, kerosene, diesel and vacuum gas oil before they become fuels or feed other units. The main reactions are:
Hydrodesulphurisation (HDS): sulphur compounds become hydrocarbons and H₂S.
Hydrodenitrogenation (HDN): nitrogen compounds become hydrocarbons and ammonia.
Hydrodemetallisation (HDM): nickel and vanadium deposit on the catalyst, which matters most for heavy feeds.
Saturation: olefins and some aromatics take up hydrogen, improving stability and cetane.
Ultra-low sulphur fuel limits have made hydrotreating one of the most important and most tested refinery processes.
Typical operating window
Variable | Typical range | Effect |
Reactor temperature | About 300 to 400 °C | Higher temperature raises conversion but speeds coking and catalyst deactivation |
Hydrogen partial pressure | Tens of bar for naphtha up to well over 100 bar for heavy feeds | Higher pressure improves HDS, HDN and aromatic saturation and slows deactivation |
Liquid hourly space velocity (LHSV) | About 0.5 to 5 h⁻¹ | Lower LHSV means more contact time and deeper treating |
Hydrogen-to-oil ratio | Set per feed, often hundreds of Nm³/m³ | Keeps catalyst wetted and supplies hydrogen for reaction and quench |
Catalyst | Sulphided CoMo or NiMo on alumina | CoMo favours HDS; NiMo favours HDN and saturation |
The exact window depends on the feed and the product specification; establishing it for a given catalyst and feed is the job of the pilot plant.
Why test at pilot scale?
Catalyst selection. Compare candidate catalysts on the refinery's own feed before buying a full reactor load.
Start-of-run temperature and cycle length. Measure activity and deactivation rate to predict run length.
Feed changes. Check how cracked stocks, biofeeds or heavier crudes change hydrogen consumption and product quality.
Process development. Generate kinetic data for licensors, catalyst developers and university programmes.
Data from a well-designed pilot plant scales to the commercial unit when the catalyst bed is properly wetted and in plug flow, which is why small reactors dilute the catalyst with fine inert particles such as silicon carbide.
What a hydroprocessing pilot plant includes
Hydrogen feed through a mass flow controller, with nitrogen for purging and pressure testing.
Liquid feed from a balance-weighed tank by a high-pressure metering pump, with heated lines for waxy feeds.
Reactor: a tubular trickle-bed reactor in a multi-zone furnace, with a multipoint thermocouple in the bed to hold isothermal conditions.
Presulphiding system: a sulphiding agent such as DMDS dosed into the feed to activate the catalyst in place.
Pressure control by a back-pressure regulator holding reactor pressure.
High- and low-pressure separators to split gas and liquid product, with level control and sampling.
Off-gas handling: gas metering, H₂S scrubbing and safe venting.
Analysis: online or offline GC for gases, and sulphur and nitrogen analysis of the liquid product.
Control and safety: PLC/SCADA with recipes, alarms and data logging, hydrogen and H₂S detectors, high-temperature and high-pressure interlocks, and a ventilated enclosure.
How to specify a hydrotreating pilot plant
Feeds to be tested and their properties (boiling range, sulphur, nitrogen, metals, wax).
Catalyst volume and particle size, and whether beds will be diluted.
Design pressure and temperature, with margin above the test window.
Range of LHSV and hydrogen-to-oil ratio, which sets pump and MFC turndown.
Number of reactors (single or parallel) and run length (unattended operation).
Product analysis required online and offline.
Hazardous-area classification, gas detection and the site's safety standards.
Data, reporting and remote monitoring needs.
Tech Inc. builds the fixed-bed catalyst test unit for hydroprocessing, FCC and reforming catalyst testing, the hydrotreating system for refining research, and high-pressure reactors for batch studies. Send your feed, catalyst volume and design conditions to mail@techincresearch.com for a proposal.
Frequently asked questions
What is the difference between hydrotreating and hydrocracking?
Hydrotreating removes heteroatoms and saturates molecules with little change in boiling range. Hydrocracking breaks heavy molecules into lighter products over an acidic catalyst at higher severity.
Why is the catalyst sulphided?
CoMo and NiMo catalysts are supplied as oxides and become active only as sulphides, so they are presulphided in the reactor before the test feed starts.
Why dilute the catalyst bed in a pilot reactor?
Small reactors run at low liquid velocities. Fine inert diluent improves wetting and plug flow so that results represent the commercial reactor.
How long is a hydrotreating pilot test?
Screening runs take days; deactivation and cycle-length studies run for weeks, which is why pilot plants are built for unattended continuous operation.





Comments