CONTACT ANGLE METER
Contact angle measurement is used to check whether the membrane surface is hydrophobic or hydrophilic.
Features & Benefits
-
Integrated method enabling to define contact angle and surface roughness accurately from the same location and to combine both surface chemical and topographical data with automated software calculations.
-
Offers fast surface characterization method, which does not demand specialist to run the samples.
-
Versatile roughness measurement: both 2D and 3D characterization.
-
Tech Inc offers economy model which enables measurement of contact angle based on image analysis and consists of the following :
-
Table to hold droplet with two axes – X & Y movement of + 30mm to adjust the focus on droplet .
-
Vertical slide of 250-300mm height movement to position and focus droplet.
-
Image sensor with USB cable
-
LED lamp to illuminate the droplet.
-
Syringe for manually transferring droplet of solution on X-Y table
-
Image captured on Laptop shall be used for measuring contact angle using standard AutoCad Software (customer’s scope)
CONTACT ANGLE GONIOMETER
MODEL : TI 300

Contact angle goniometer refers to the tangent of the gas-liquid interface at the intersection point C of gas, liquid and solid, and the included angle between the tangent on the liquid side and the solid-liquid boundary line is a measure of wetting degree. It is the main method of surface performance testing at present. The contact angle and surface energy of the sample surface are measured by the principle of optical imaging-image profile analysis. It is mainly composed of light source, injection unit, sample table, acquisition system and analysis software. The equipment adopts differential precision liquid inlet device, which has high cost performance, strong expansibility and comprehensive functions, and can meet all kinds of conventional measurement requirements. At present, it has been widely used in many universities and enterprises.
-
Measuring range of the Contact Angle: 0° 180°
-
Measuring range for Surface Tension and Interfacial Tensions: 0.01 - 2000 mN/m or better
-
Resolution: ± 0.01mN/m or better.
-
Optical System with 3 steps zoom lens, continuously variable focal length
-
LED lighting with two steps manual intensity control with integrated light blind and vertically adjustable.
-
Camera system:- maximum frame rate 2700 frames/s or better
-
Axes and sample stages The sample stage size Shall be 100 x 100 mm (L x W) with flexible positioning in x-y directions with integrated level and sample clamps
-
Windows/Linux based Software Shall be offered
CONTACT ANGLE GONIOMETER
MODEL : TI 150

The Lab Contact Angle Meter (Model TI 150) is an advanced optical imaging–based instrument designed for accurate measurement of surface wettability and surface free energy. It works on the image profile analysis principle and uses Sessile Drop and Pendant Drop methods for contact angle and surface tension measurement. The instrument offers a wide contact angle range of 0°–180° and surface tension measurement from 0–100 mN/m, with high resolution of 0.01° and accuracy of ±0.3°. It is equipped with an LED light source, high-speed camera (≥30 fps) with USB 3.0 interface, and fully automated analysis software supporting multiple evaluation methods such as Young-Laplace, Owens-Wendt, Acid-Base, and other surface energy models. The system accommodates sample sizes up to 100 × 100 × 10 mm, includes Z-axis stage movement greater than 10 mm, and features a manual droplet dispenser with minimum 1 µl capacity. With a compact footprint (≤175 × 350 × 300 mm) and lightweight design (≤3 kg), it is suitable for laboratory environments and plug-and-play operation. The equipment is widely used for plasma cleaning analysis, surface treatment evaluation, adhesion studies, semiconductor manufacturing, glass processing, coatings, textiles, and medical and biological research applications.