Pulse Decay Permeability: Measuring Nanodarcy Rock

At a glance. In a pulse decay test the core sits between two gas reservoirs at the same pressure under confining stress. A small pressure step is applied upstream and the decay of the pressure difference over time gives permeability. The Tech Inc. Pulse Decay Permeameter measures from about 0.01 µD to 10 mD.
Why not steady state?
At nanodarcy permeability, flow through a plug is so small that it takes days to stabilise and is lost in leaks and temperature drift. Pulse decay uses the transient instead, with a sensitive differential transducer.
Getting good data
Temperature stability: small temperature changes move pressures more than the decay itself.
Leak checks: test with a steel dummy plug.
Reservoir volumes matched to the expected pore volume.
Net stress: report the confining and pore pressures used.
Klinkenberg: test at several pore pressures to correct for gas slippage.
Typical uses
Shale gas and tight oil reservoirs.
Caprock and fault seals for CO2 storage.
Cement and concrete barriers.
Frequently asked questions
Crushed rock or plugs? Plugs give permeability under stress; crushed-rock methods are quicker but give matrix values without stress.
Can it also give porosity? Yes, our combined model adds Boyle's law porosity.
Ask mail@techincresearch.com about your samples.